Outlets; Start Dial (Off/Run/Choke); Usb Ports; Eco Mode Switch - Craftsman CMXGIAC3000 Instruction Manual

Inverter generator
Table of Contents

Advertisement

Available languages

Available languages

Outlets

120 VAC, Duplex Outlet
The 120 Volt outlet is overload protected by the 20 Amp
push button circuit protector
Fig. C
120 VAC, 30 Amp Outlet
Use a NEMA L5-30R plug with this outlet. Connect a suit-
able 3-wire cord set to the plug and to desired load. The
cord set should be rated for 125 Volts AC at 30 Amps (or
greater)
(Fig.
D).
Use this outlet to operate 120 Volt AC, 60Hz, single
phase loads requiring up to 3000 watts, 25 Amps start-
ing power and 2300 watts of continuous power at 19.1
Amps. The outlet is protected by a 20 Amp push-to-reset
circuit breaker.
Fig. D

Start Dial (Off/Run/Choke)

This controls the ON/OFF functions, choke and fuel valve
operation
(Fig.
E).
• The OFF position
1
flow.
• The RUN position
gradually reduce the use of the choke.
• The CHOKE position
start the engine.
NOTE: The CHOKE is not required to start a warm engine.
6
(Fig.
C).
stops the engine and shuts off fuel
is for normal operation and to
2
switches the fuel valve on to
3
Fig. E

USB Ports

The 1 Amp and 2.1 Amp USB outlets allow charging of
compatible electronic devices.
001630

Eco Mode Switch

The economy switch has 2 modes of operation:
• On: The quietest mode and best when running appli-
ances or equipment that are resistive loads (non-motor
starting), (example: TV, video game, light, radio).
• Off: Best when running a both inductive (motor-start-
ing loads) and resistive (non-motor starting loads),
especially when these loads are turning on and off
(example: RV, air conditioner, hairdryer).

Generator Status Lights

See
Fig.
F.
• Overload LED (red): Indicates system overload
During motor starting it is normal for the overload LED
to illuminate for a few seconds. If LED stays illuminated
and the ready LED turns off, the engine will continue to
run without output power. Remove all applied loads
and determine if attached devices exceed recom-
mended output power. Check for faulty or shorted con-
nections. To restore electrical output, turn dial OFF to
reset. Start engine. If condition was corrected, the red
LED will not illuminate and electrical output will be
restored. Loads can be applied once the green LED illu-
minates. If the orange LED returns, contact a Service
000844
Dealer.
• Low Oil Level LED (yellow): Illuminates when oil level
is below safe operating level. Engine shuts down
• Power LED (green): Indicates output from generator
(unless there is a low oil or overload condition).
3
Fig. F
OFF
CHOKE
3
2
1
1
2
ON
3
005482
.
2
.
1
005483