  • Page 1 Preface Introduction Installing the Device RUGGEDCOM RSL910 Communication Ports Technical Specifications Dimension Drawings Installation Guide Certification 10/2016 RC1305-EN-01...
  • Page 2 Warranty Siemens warrants this product for a period of five (5) years from the date of purchase, conditional upon the return to factory for maintenance during the warranty term. This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void.
  • Page 3 RUGGEDCOM RSL910 Installation Guide Contacting Siemens Address Telephone E-mail Siemens Canada Ltd Toll-free: 1 888 264 0006 ruggedcom.info.i-ia@siemens.com Industry Sector Tel: +1 905 856 5288 300 Applewood Crescent Fax: +1 905 856 1995 Concord, Ontario www.siemens.com/ruggedcom Canada, L4K 5C7...
  • Page 4 RUGGEDCOM RSL910 Installation Guide...
  • Page 5: Table Of Contents

    RUGGEDCOM RSL910   Installation Guide Table of Contents Table of Contents Preface ......................Alerts ..............................vii Related Documents ..........................vii Accessing Documentation ........................viii Training ............................viii Customer Support ..........................viii Chapter 1 Introduction ..................... 1.1  Feature Highlights ........................1 1.2    Description ........................... 2 Chapter 2 Installing the Device ..................
  • Page 6   RUGGEDCOM RSL910 Table of Contents Installation Guide Chapter 4 Technical Specifications .................. 4.1  Power Supply Specifications ......................25 4.2  Failsafe Relay Specifications ......................25 4.3  Copper Ethernet Port Specifications ....................26 4.4  Operating Environment ....................... 26 4.5  Mechanical Specifications ......................26 Chapter 5 Dimension Drawings ..................
  • Page 7: Preface

    Installation Guide Preface Preface This guide describes the RUGGEDCOM RSL910. It describes the major features of the device, installation, commissioning and important technical specifications. It is intended for use by network technical support personnel who are responsible for the installation, commissioning and maintenance of the device.
  • Page 8: Accessing Documentation

    Siemens Sales representative. Customer Support Customer support is available 24 hours, 7 days a week for all Siemens customers. For technical support or general information, contact Siemens Customer Support through any of the following methods: Online Visit http://www.siemens.com/automation/support-request...
  • Page 9: Introduction

    RUGGEDCOM RSL910 to be placed in almost any location. The RUGGEDCOM RSL910 can be mounted on a DIN rail or panel for efficient use of cabinet space. The integrated power supply supports a wide range of voltages (88-300 VDC or 85-264 VAC) for worldwide operability, as well as dual-redundant, reversible polarity, 24 VDC and 48 VDC power supply inputs for high availability applications requiring dual or backup power inputs.
  • Page 10: Description

    • CSA/UL 60950-1 safety approved to 85 °C (185 °F) Section 1.2 Description The RUGGEDCOM RSL910 features various ports, controls and indicator LEDs on the front panel for connecting, configuring and troubleshooting the device. Figure 1:  RUGGEDCOM RSL910 1. POWER LED    2. ALARM LED    3. RS232 Console Port (USB Type-B)    4. [Optional] SFP (100/1000Base-TX/FX/SX/LX) Ethernet Ports   ...
  • Page 11 Section 2.5, “Connecting to the Device” Communication Ports Receive and transmit data, as well as provide access to the RUGGEDCOM ROS Web interface. For more information about the various ports available for the RUGGEDCOM RSL910, refer to Chapter 3, Communication Ports Failsafe Alarm Relay Latches to default state when a power disruption or other alarm condition occurs.
  • Page 12 RUGGEDCOM RSL910 Chapter 1 Installation Guide Introduction Description...
  • Page 13: Installing The Device

    This product contains no user-serviceable parts. Attempted service by unauthorized personnel shall render all warranties null and void. Changes or modifications not expressly approved by Siemens Canada Ltd could invalidate specifications, test results, and agency approvals, and void the user's authority to operate the equipment.
  • Page 14: Required Tools And Materials

    Section 2.2 Mounting the Device The RUGGEDCOM RSL910 is designed for maximum mounting and display flexibility. It can be equipped with adapters that allow it to be installed on a 35 mm (1.4 in) DIN rail or affixed to a panel.
  • Page 15: Mounting The Device To A Panel

    Section 2.2.2 Mounting the Device to a Panel For panel installations, the RUGGEDCOM RSL910 can be equipped with panel adapters on the top and bottom of the chassis. The adapters allow the device to be attached to a panel using screws.
  • Page 16: Connecting Power

    Secure the adapters to the panel with #6-32 screws. Section 2.3 Connecting Power The RUGGEDCOM RSL910 supports power input from a single high AC/DC or low DC power supply. IMPORTANT! • For 110/230 VAC rated equipment, an appropriately rated AC circuit breaker must be installed.
  • Page 17: Connecting High Ac/Dc Power

    Installing the Device IMPORTANT! Siemens requires the use of external surge protection in VDSL applications where the line may be subject to surges greater than that for which the device is rated. Use the following specifications as a guide for VDSL external surge protection: •...
  • Page 18: Connecting Low Dc Power

    Section 2.3.2 Connecting Low DC Power RUGGEDCOM RSL910's equipped with 24 or 48 V power supply inputs feature reverse polarity protection and dual power supply inputs allowing the device to accept redundant connections to a single DC power supply. To connect a low DC power supply to the device, do the following: NOTE Torque all terminal connections to 0.6 N·m (5 lbf-in).
  • Page 19 RUGGEDCOM RSL910 Chapter 2 Installation Guide Installing the Device ± ± Figure 6: Terminal Block Wiring - Single DC Power Supply Inputs 1. Positive Terminal    2. Negative Terminal    3. Surge Ground Terminal    4. Braided Ground Cable Connect the negative wire from the power source to the negative terminal on the terminal block.
  • Page 20: Connecting The Failsafe Alarm Relay

    Control of the failsafe relay output is configurable through ROS. One common application for this relay is to signal an alarm if a power failure occurs. For more information, refer to the ROS User Guide for the RUGGEDCOM RSL910. The following shows the proper relay connections.
  • Page 21: Connecting To The Device

    Connecting to the Device The following describes the various methods for accessing the ROS console and Web interfaces on the device. For more detailed instructions, refer to the ROS User Guide for the RUGGEDCOM RSL910. IMPORTANT! Ethernet cables should be only be connected/disconnected in a non-hazardous area, or when the device is not energized.
  • Page 22 Chapter 2 RUGGEDCOM RSL910 Installing the Device Installation Guide Figure 9: Console Ports 1. USB Type-B Console Port    2. Serial DB9 Console Port Pin-Out The serial console port implements RS232 DCE (Data Communication Equipment) on a DB9 connector. The following is the pin-out for the port:...
  • Page 23: Cabling Recommendations

    Siemens also does not recommend using copper Ethernet ports to interface with devices in the field across distances that could produce high levels of ground potential rise (i.e. greater than 2500 V), during line-to-ground fault conditions.
  • Page 24 RUGGEDCOM RSL910 Chapter 2 Installation Guide Installing the Device Cabling Recommendations...
  • Page 25: Communication Ports

    Chapter 3 Installation Guide Communication Ports Communication Ports The RUGGEDCOM RSL910 can be equipped with various types of communication ports to enhance its abilities and performance. Figure 11: Port Assignment 1. Ports 7 and 8    2. Ports 1 to 6    3. Port 9 and 10...
  • Page 26: Copper Ethernet Ports

    Section 3.1 Copper Ethernet Ports The RUGGEDCOM RSL910 supports multiple 10/100Base-TX Ethernet ports that allow connection to standard Category 5 (CAT-5) unshielded twisted-pair (UTP) cables with RJ-45 male connectors. The RJ-45 receptacles are directly connected to the chassis ground on the device and can accept CAT-5 shielded twisted-pair (STP) cables.
  • Page 27: Eovdsl Ports

    Section 3.2 EoVDSL Ports The RUGGEDCOM RSL910 features a pluggable terminal block that supports up to two Universal EoVDSL connections. Universal EoVDSL connections are Master/Slave selectable and offer symmetric data rates up to 85 Mbps with distances up to 3 km (1.8 mi).
  • Page 28: Eovdsl Wiring

    Chapter 3 RUGGEDCOM RSL910 Communication Ports Installation Guide Terminal Description Receive on Port 9 Transmit from Port 9 Receive on Port 10 Transmit from Port 10 Figure 14: EoVDSL Terminal Block CONTENTS • Section 3.2.1, “EoVDSL Wiring” • Section 3.2.2, “Configuration and Setup” •...
  • Page 29: Configuration And Setup

    Section 3.2.2 Configuration and Setup If the RUGGEDCOM RSL910 and another device both have Universal EoVDSL ports, configure one device to be the Master and the other the Slave. Once configured and connected together, each device will attempt to achieve the maximum speed based on the line length and conditions.
  • Page 30: Sfp Transceivers

    2896 m (9500 ft) Section 3.3 SFP Transceivers The RUGGEDCOM RSL910 supports up to two Small Form-Factor Pluggable (SFP) transceiver sockets, which are compatible with a wide array of SFP transceivers available from Siemens. LEDs Each socket features an LED that indicates its link state.
  • Page 31 Link established Green (Blinking) Activity No link detected Compatible SFP Transceivers The following SFP transceivers are compatible with the RUGGEDCOM RSL910. For more information, including installation/removal instructions and ordering information, refer to the RUGGEDCOM SFP Transceiver Catalog [https://support.industry.siemens.com/cs/ca/en/view/109482309] . IMPORTANT! Only use SFP transceivers approved by Siemens for RUGGEDCOM products.
  • Page 32 RUGGEDCOM RSL910 Chapter 3 Installation Guide Communication Ports SFP Transceivers...
  • Page 33: Technical Specifications

    RUGGEDCOM RSL910 Chapter 4 Installation Guide Technical Specifications Technical Specifications This section provides important technical specifications related to the device. CONTENTS • Section 4.1, “Power Supply Specifications” • Section 4.2, “Failsafe Relay Specifications” • Section 4.3, “Copper Ethernet Port Specifications” • Section 4.4, “Operating Environment”...
  • Page 34: Copper Ethernet Port Specifications

    Chapter 4 RUGGEDCOM RSL910 Technical Specifications Installation Guide Section 4.3 Copper Ethernet Port Specifications The following details the specifications for copper Ethernet ports that can be ordered with the RUGGEDCOM RSL910. Wiring Maximum Speed Connector Duplex Cable Type Isolation Standard Distance...
  • Page 35: Dimension Drawings

    RUGGEDCOM RSL910 Chapter 5 Installation Guide Dimension Drawings Dimension Drawings NOTE All dimensions are in millimeters, unless otherwise stated. 124.7 65.1 116.6 Figure 15: Overall Dimensions...
  • Page 36 Chapter 5 RUGGEDCOM RSL910 Dimension Drawings Installation Guide 78.8 120.6 13.7 101.6 ø 8.1 ø 4.0 ø 4.0 57.2 Figure 16: Panel Mount Dimensions...
  • Page 37 RUGGEDCOM RSL910 Chapter 5 Installation Guide Dimension Drawings 126.2 134.3 Figure 17: DIN Rail Mount Dimensions...
  • Page 38 RUGGEDCOM RSL910 Chapter 5 Installation Guide Dimension Drawings...
  • Page 39: Certification

    60950-1) • UL 60950-1 Information Technology Equipment – Safety Part 1: General Requirements Section 6.1.2 European Union (EU) This device is declared by Siemens Canada Ltd to comply with essential requirements and other relevant provisions of the following EU directives: Approvals...
  • Page 40: Fcc

    Information Technology Equipment – Radio Disturbance Characteristics – Limits and Methods of Measurement The device is marked with a CE marking and can be used throughout the European community. A copy of the CE Declaration of Conformity is available from Siemens Canada Ltd. For contact information, refer to “Contacting Siemens ”...
  • Page 41: Other Approvals

    Railway applications – Electromagnetic Compatibility – Rolling Stock Apparatus • NEMA TS-2 Traffic Controller Assemblies with NTCIP Requirements Section 6.2 EMC and Environmental Type Tests The RUGGEDCOM RSL910 has passed the following Electromagnetic Compatibility (EMC) and environmental tests. EMC Type Tests Test Description Test Levels...
  • Page 42 Chapter 6 RUGGEDCOM RSL910 Certification Installation Guide Test Description Test Levels Severity Levels 1000 A/m for 1 s IEC 61000-4-11 Voltage Dips and Interrupts AC Power Ports 100% for 5 Periods 100% for 50 Periods Environmental Type Tests Test Description...