L Specifications
Item
Connected scale unit
Resolution
Maximum response speed
Maximum response acceleration
Cable length
Power voltage
Power consumption
Operating temperature
Strage temperature
Mass
Supplied accessories
The power consumption of 1 W marked with
*
MT11 stands for the output to a differential output
load of 120 Z.
L MT11 output specifications
Output signal
Output format
Phase A/Phase B phase difference
Travelling velocity : v [m/min]
0<v<12.5
12.5≦v<32.5
32.5≦v≦60.0
Alarm signal : This signal is output when the response acceleration is
exceeded or when a scale unit is not connected. The minimum
output pulse width is 10 ms, and the alarm output signal also
recovers automatically when the alarm status is canceled.
L Optional Accessories
Extension cable
(These are extension cables for use between scale unit and the detector.)
CE08-1 (1 m)
CE08-3 (3 m)
CE08-5 (5 m)
CE08-10 (10 m)
CE08-15 (15 m)
Specifications and appearances of the products are subject to change without notice because of improvement.
2 (E)
Model
MT10/MT11
DT12N/DT12P
5µ m
60 m/min
2
2400 m/s
0.3 m/0.98 ft
DC5 V ±4%
0.7 W (MT10),
*
1 W (MT11)
0 to 50°C/32 to 122°F
–10 to 60°C/14 to 140°F
About 90 g
Instruction manual
: A/B phase, Alarm
: Differential line driver (equivalent to EIA-422)
: Changes as follows according to the travelling velocity of the scale unit.
(Sampling is performed every 120 µs.)
Phase difference : T [µs]
20.0
8.8
4.5
L MT11 cable color
Cable color
Signal
Red
Power supply +5V
White
Power supply 0V
Brown
Power supply 0V
Black
Power supply 0V
Yellow
A
Blue
A
Gray
B
Orange
B
Purple
ALARM
Green
ALARM
Shield
FG
Power supply 0V (white, brown and black) and
the shield are connected with a capacitor.
(isolated with respect to DC)