AEG CGB6133CCM User Manual page 27

Table of Contents

Advertisement

Dimension
A
B
C
D
E
13.8 Pressure test
The Rapid injector is used as a pressure
test point.
1. Connect the pressure gauge to the
Rapid injector.
2. Examine the supply pressure by
turning the Rapid burner and one
other burner fully on, and lighting
them. The pressure must be 20 mbar
for Natural Gas.
3. Turn the taps off and disconnect the
pressure gauge.
4. Make sure that all burners work
correctly.
13.9 Checking the hob burners
1. Lift the lid.
2. Put on the burner crowns and caps.
Make sure that they are correctly
seated.
3. Put on the pan supports.
4. Light one of the hob burners.
To light the hob burner refer to the
"Ignition of the hob burners".
Check if the flame is regular.
Check each of the burners.
5. Turn the knob for the hob to the off
position.
13.10 Checking the oven
burners
1. Put in the deep pan and the trivet.
2. Light the oven burner.
To light the oven burner refer to the
"Ignition of the oven burners".
mm
250
680
50
250
580
Check if the flame is regular.
3. Turn the knob to the off position.
13.11 Checking the Lid Safety
Device
1. Lift the lid.
2. Light one of the hob burners.
To light the hob burner refer to the
"Ignition of the hob burners".
3. Close the lid. There should be no gas
supply to the hob burners. The
burner goes out.
4. Turn the knob to the off position and
lift the lid. The gas supply should be
restored to the hob burners, when
you turn the knob on.
13.12 Electrical installation
WARNING!
The manufacturer is not
responsible if you do not
follow the safety precautions
from Safety chapters.
This appliance is supplied with a main
plug and a main cable.
The spark generator is active
all the time if the phases are
not connected correctly.
WARNING!
The power cable must not
touch the part of the
appliance shaded in the
illustration.