Printed Circuit Board Data; After Changing The Pcb; Attaching The Ecn Label - Kenwood NX-720 Service Manual

Vhf digital transceiver
Hide thumbs Also See for NX-720:
Table of Contents

Advertisement

■ Method of confi rming "Original TX-RX unit" and
"Service TX-RX unit"
SUPPLIED ACCESSORIES
ESN Label ..................................................................... 1
• KENWOOD ESN
• NXDN ESN
• MPT ESN
Addendum ..................................................................... 1

PRINTED CIRCUIT BOARD DATA

The following data is written on the printed circuit board:
Data Type
Firmware
NX-720/820 K type fi rmware
FPU Data
X57-823: NX-720 Kx type data
(PC programming
X57-824: NX-820 Kx type data
mode)
Voice Language
English
Various Adjustment
General adjustment values for the X57-823
Data (PC Test mode)
(NX-720), and X57-824 (NX-820).
Model Name:
136~174MHz
NX-720HGS: X57-8230-12 (for GPS model)
NX-720HS: X57-8230-13
• 400~470MHz
KENWOOD ESN
NX-820HGS: X57-8240-16 (for GPS model)
NX-820HS: X57-8240-17
Type : Kx
The same number as the KENWOOD ESN
label is written.
NXDN ESN/MPT
The same number as the NXDN ESN/ MPT
ESN
ESN label is written.
ATTACHING THE ESN LABEL
TROUBLE SHOOTING
Description
NX-720(G)/720

AFTER CHANGING THE PCB

1. After changing the printed circuit board, write the up-
to-date Firmware following the instructions in the "RE-
ALIGNMENT- 6. Firmware Programming Mode".
• Write the Firmware in accordance to the Market. If you
write different Market Firmware, there are times commu-
nication with the FPU is not possible.
2. Using the KPG-141D, select your desired item (Model
Name and Frequency) from the Model > Product Informa-
tion menu, then use Program > Write Data to the Trans-
ceiver to write the FPU data (PC Programming mode).
When writing to the transceiver, a Warning Message, cor-
responding to the item selected, appears. Click [OK] to
continue writing the data.
3. Enter Program > Test Mode, then adjust the various ad-
justment data (PC Test mode) as described in the "AD-
JUSTMENT".
4. Attach the new labels corresponding to the new printed
circuit board. (Refer to the images below for label place-
ment.)
5. If necessary, write the FPU data used by the customer
with the KPG-141D.
Note:
• When using the ESN Validation function of Trunking, the
ESN number changes when the circuit board is changed
(the number is written on the circuit board); the Trunking
system cannot be accessed. Maintain the ESN data of
the Trunking System following the new ESN.
• When a new printed circuit board is used, the KENWOOD
ESN changes, as does the Transceiver Information dis-
play of the KPG-141D, but this does not have any effect
on the operation of the transceiver.
• If changing to the original ESN, please contact our ser-
vice center.
ESN Label
1234567891012
S/NO.
B2700001
Place the separated KENWOOD
M1234567890
ESN/NXDN ESN/MPT ESN
label on top of the original label.
N12456789012
Cut line
S/NO. BXXXXXXX
MXXXXXXXXXX
NXXXXXXXXXXXX
Remove the KENWOOD
ESN/NXDN ESN/MPT ESN
label along the cut line.
S/NO. BXXXXXXX
MXXXXXXXXXX
NXXXXXXXXXXXX
33

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Nx-720g

Table of Contents