Panasonic ECG2111 Operating Instructions Manual page 5

Emergency portable cellular telephone
Table of Contents

Advertisement

Applicant: Matsushita Electric Works, Ltd.
(1) CALL Button
Emergency Call Origination will be initiated when pushed for 1 second.
After connecting with Emergency Response Center (ERC), the unit acts according to a command received from
ERC. If the unit was not able to connect with ERC, it does dialing to 911.
VMS: Veterans Monitor System
(2) TEST Button
This button will be used to test the unit.
a) Battery status
b) Communication between AMPS cpu and GPS module
c) Actual operation with the AMPS RSSI level and the control channel detection
(3) IN USE Indicator
This LED Indicates the Operation condition:
Flashing Green:
Indicates the call in progress and till Help-Enroute established.
Solid Green:
Indicates the active Help-Enroute command is received.
(4) TEST Indicator
This LED indicates the Self Test condition:
Flashing Green:
Indicates the GPS module communication is error.
Or+
Indicates the AMPS RSSI Signal is too weak or No Service.
Solid Green:
Indicates the GPS module communication is OK.
And
Indicates the AMPS RSSI Signal is acceptable and the control channel was detected.
(5) BATTERY Indicator
This LED indicates the Battery status:
Flashing Green:
Indicates the Battery status is low.
Solid Green:
Indicates the Battery status is acceptable.
(6) Speakerphone
Even in case the location by using GPS cannot be caught, it is possible to make voice call to ERC operator or 911
operator by using Speakerphone and Microphone without lifting up this unit near users ear.
(7) GPS Antenna
(8) AMPS Antenna
(9) Microphone
(10) Siren Speaker
The unit sounds siren in the following cases;
1) In case Activate Siren command is received from Emergency Response Center (ERC).
2) In case connection cannot be made to ERC to 911.
3) In case TEST button is held for 4 seconds to make Siren test
A period of siren is ON (2sec), OFF (8sec)
(11) Battery Compartment
(12) External Input
By connecting EMERGENCY BUTTON (Optional) prepared outside to this terminal, it is possible to make the
operation same as pressing VMS (Emergency Call) of unit itself.