Canon Service Bulletin COPIER Issued by Canon Europa N.V. Model: Ref No.: iR6800C iR6800C-010 iR6800CN (F2-T01-0M3-10027-01) Date: 30-07-04 Location: Vertical Size Detection Kit Installation Subject: Remedy Against the Glare of Scanning Lamp Background Reports of users complaining about the glare of the scanning lamp have been filed, and a vertical size sensor kit (AB/ Inch) will be offered as a remedial kit.
Page 2
iRC6800-010 Note: As opposed to the use of a CCD, the use of a reflection type sensor will not permit detection of the following: for AB-configuration, absence of paper, B6, A5; for Inch-configuration, absence of paper, STMT, STMT-R. Installation Procedure When installing the Vertical Size Sensor Kit (Inch;...
Page 3
iRC6800-010 2.Installation 2.1 Installing to the Host Machine Be sure to go through the following in strict sequence before starting the work: 1. Turn off the control panel power switch [1]. 2. Turn off the main power switch [2]. 3. Disconnect the power cable [3] from the power outlet. [1] OFF ON/OFF 1) Remove the 2 screws, and detach the right glass retainer [2];...
Page 4
iRC6800-010 2) Remove the 2 screws [1], and detach the reader unit right cover [2]. 3) Remove the 9 screws [1], and detach the CCD unit cover [2]. (4/10)
Page 5
iRC6800-010 4) Remove the 3 screws [1]. 5) Lift the original size detection unit [1] slightly;then, disconnect the connector [2]. (5/10)
Page 6
iRC6800-010 6) Mount the included horizontal size sensor [1] to the original size detection unit [2]. Note: Pay attention to the location of mounting, as it differs between AB-configuration and Inch- configuration. - AB-Configuration - Inch-Configuration F-10 (6/10)
Page 7
iRC6800-010 7) Fit the harness [1] to the connector [2]. - AB-Configuration F-11 - Inch-Configuration F-12 8) Secure the original size detection unit [1] in place using 3 screw [2]. F-13 (7/10)
Page 8
iRC6800-010 9) Secure the vertical size sensor unit [1] in place using a screw [2]. F-14 10) Fit the included clamp [1] into the hole [2]. There are multiple holes. Be sure to use the correct hole. (Do not use the hole identified as [3].) F-15 (8/10)
Page 9
iRC6800-010 11) Fit the included edge saddle [1] as shown. F-16 If an edge saddle already exists, skip this step. 12) Fix the harness [1] in place using 5 clamps [2] and the edge saddle [3]. F-17 (9/10)
Page 10
iRC6800-010 13) Route the harness [1] through the original size detection unit [2]; then, connect it to the connector [3]. F-18 14) Mount the CCD unit cover, copyboard glass, right glass retainer, and reader right coverby following the steps used to detach them but in reverse. 15) Connect the power cable to the power outlet, and turn on the main power switch.