GENERAL POWER TOOL SAFETY WARNINGS


WARNING! Read all safety warnings and all
instructions. Failure to follow the warnings and
instructions may result in electric shock, fire and/or
serious injury.
SAVE ALL WARNINGS AND
INSTRUCTIONS FOR FUTURE
REFERENCE
Safety Rules for Corded Power Supply

DANGER: High voltage present inside the unit.
Do not probe with conductive objects. Danger of
electric shock or electrocution.

DANGER: If the corded power supply case is
cracked or damaged, do not plug into AC outlet
or insert into tool. Return the unit to an authorized
D
WALT service center. Danger of electric shock
e
or electrocution.

DANGER: The corded power supply and power
tool may produce a small magnetic field. Users
with cardiac pacemakers should keep the corded
power supply and power tool at least 6" (15 cm)
away from implanted device. Users should
immediately stop using this product, remove
power, and call physician if any physical effects
are felt.
Do not use under wet conditions or in presence of
flammable liquids or gases.
Do not expose corded power supply to rain or snow.
Use of an attachment not recommended or sold by
D
WALT may result in a risk of fire, electric shock, or injury
e
to persons.
This corded power supply is not intended for any uses
other than powering D
WALT 120 V Max* FLEXVOLT™
e
tools. Any other uses may result in risk of fire, electric shock
or electrocution.
Pull by the plug rather than the cord when
disconnecting the corded power supply. This will
reduce the risk of damage to the electric plug and cord.
Make sure that the cord is located so that it will not
be stepped on, tripped over or otherwise subjected
to damage or stress.
Do not use an extension cord unless it is absolutely
necessary. Use of improper extension cord could result in
risk of fire, electric shock or electrocution.
When operating the corded power supply
outdoors, always provide a dry location and use an
extension cord suitable for outdoor use. Use of a cord
suitable for outdoor use reduces the risk of electric shock.
An extension cord must have adequate wire size
(AWG or American Wire Gauge) for safety. The smaller
the gauge number of the wire, the greater the capacity
of the cable, that is, 16 gauge has more capacity than 18
gauge. An undersized cord will cause a drop in line voltage
resulting in loss of power and overheating. When using
more than one extension to make up the total length, be
sure each individual extension contains at least the
2
minimum wire size. The following table shows the correct
size to use depending on cord length and nameplate
ampere rating. If in doubt, use the next heavier gauge. The
lower the gauge number, the heavier the cord.
Minimum gauge for Cord sets
Total length of Cord in Feet
Volts
120 V
25 (7.6)
240 V
50 (15.2) 100 (30.5) 200 (61.0) 300 (91.4)
Ampere Rating
More
not
American Wire gauge
Than
More
Than
0
6
18
6
10
18
10
12
16
12
16
14
The label on your tool may include the following symbols. The
symbols and their definitions are as follows:
V ......................... volts
Hz ....................... hertz
min ..................... minutes
or DC ...... direct current
...................... Class I Construction
(grounded)
.../min .............. per minute
BPM .................... beats per minute
IPM ..................... impacts per minute
RPM .................... revolutions per
minute
sfpm ................... surface feet per
minute
SPM .................... strokes per minute
A ......................... amperes
W ........................ watts
or AC ........... alternating current
SAVE THESE INSTRUCTIONS FOR
FUTURE USE
COMPONENTS (FIG. A)

WARNING: Never modify the power tool or any part
of it. Damage or personal injury could result.
Refer to Figure A at the beginning of this manual for a
complete list of components.

Intended Use

This corded power supply is designed for professional use in
D
WALT 120 V Max* FLEXVOLT™ tools.
e
DO nOT use under wet conditions or in presence of
flammable liquids or gases.
This corded power supply is a professional power tool.
DO nOT let children come into contact with the tool.
Supervision is required when inexperienced operators use
this tool.
(meters)
50 (15.2) 100 (30.5) 150 (45.7)
16
16
14
16
14
12
16
14
12
12
Not Recommended
or AC/DC .... alternating or
direct current
...................... Class II
Construction
(double insulated)
n o ....................... no load speed
n ......................... rated speed
...................... earthing terminal
..................... safety alert symbol
..................... visible radiation
..................... wear respiratory
protection
..................... wear eye
protection
..................... wear hearing
protection
..................... read all
documentation