Option 1: 12 Hardwired Position Switch - Bosch DDU 7 Manual

Display unit
Table of Contents

Advertisement

Display Unit DDU 7
Page 2 is shown with 1.5 <= the value < 2.5
Page 3 is shown with 2.5 <= the value < 3.5
...
Page 12 is shown with 11.5 <= the value
Brightness switch
The brightness can be switched with 6 positions. In the display settings dialog you will find a
chart for the 6 switch positions over the display brightness and the LED brightness (the values
are in percent).
If the channel value does not only consist of integers, the pages will be switched as follows:
Switch 1 is shown with the value < 1.5
Switch 2 is shown with 1.5 <= the value < 2.5
Switch 3 is shown with 2.5 <= the value < 3.5
...
Switch 6 is shown with 5.5 <= the value
8.4.2

Option 1: 12 Hardwired position switch

1.
2.
3.
4.
Bosch Motorsport
Connect a 6 or 12 position switch to one of the analog input pins ANAxx and to the
sensor ground.
For recommended position switches, please see the environment section in the chapter
"Technical Data."
Select one of the analog inputs in the project tree.
Go to 'Measurement Sources' in the toolbox and select the 'Characteristic Curve' under
'Analog sources'. Drag and drop it on the selected analog input channel in the project
tree.
Select "Pull-up value:" 3.01 kOhm and click on 'Next'.
Manual
Display Configuration | en
04.02.2019 | V 02 |
45

Advertisement

Table of Contents
loading

Table of Contents