2.6

Technical data

This appliance meets the requirements specified by the European Directives 2014/35/EC and 2014/30/EC.
Technical data
General Information
Capacity
Dry weight
Weight when full
Standing loss
Water data
Max. permissible operating pressure
Water connections
Electrical data
Rated output
Heat-up time (T- 50 °C)
Supply voltage
Frequency
Electrical current (single phase)
Power cable with plug (type)
Protection class
IP-Rating
DHW temperature
Temperature range
Table 4
Technical data
Technical data
General Information
Capacity
Dry weight
Weight when full
Standing loss
Water data
Max. permissible operating pressure
Water connections
Electrical data
Rated output
Heat-up time (T- 50 °C)
Supply voltage
Frequency
Electrical current (single phase)
Power cable with plug (type)
Protection class
IP-Rating
DHW temperature
Temperature range
Table 5
Technical data
Tronic 4000 T | Tronic 6000 T
Units
ES 050
l
48
kg
18,8
kg
66,8
kW/24h
0,73
bar
inch
W
1500
1 h 52 min 2 h 14 min 2 h 47 min 3 h 22 min 4 h 09 min
VAC
Hz
A
6,5
°C
Units
ES 035
l
34
kg
15,7
kg
49,7
kW/24h
0,78
bar
inch
W
1200
1 h 40 min 1 h 44 min 2 h 14 min 2 h 46 min 3 h 21 min 3 h 27 min
VAC
Hz
A
5,2
HO5VV - F 3 x 1,5 mm
°C
Technical properties and dimension's | 5
Tronic 4000 T
ES 080
ES 100
77
95
22,5
25,8
99,5
120,8
0,91
1,03
8
1/2
2000
2000
230
50
8,7
8,7
2
HO5VV - F 3 x 1,5 mm
or HO5VV - F 3 x 1,0 mm
I
IP24
up to 70 °C
Tronic 6000 T
ES 050
ES 080
ES 100
47
76
19,2
22,5
66,2
98,5
120,8
0,73
0,91
8
1/2
1600
2000
2000
230
50
6,9
8,7
2
or HO5VV - F 3 x 1,0 mm
I
IP24
up to 70 °C
ES 120
ES 150
115
143
29,3
35
144,3
178
1,28
1,43
2000
2000
8,7
8,7
2
ES 120
ES 150
95
115
142
25,8
29,3
35
144,3
177
1,03
1,28
1,43
2000
2400
8,7
8,7
10,4
2
6 720 818 731 (2016/07)