1. SAFETY
Electrical Safety
WARNING! it is the user's responsibility to check the following:
check all electrical equipment and appliances to ensure that they are safe before using. inspect power supply leads, plugs and
all electrical connections for wear and damage. sealey recommend that an rcd (residual current device) is used with all electrical
products. You may obtain an rcd by contacting your local sealey dealer.
if the charger is used in the course of business duties, it must be maintained in a safe condition and routinely PAt (Portable Appliance
test) tested.
electrical safety information, it is important that the following information is read and understood.
1.0.1.
ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply.
1.0.2.
regularly inspect power supply cables and plugs for wear or damage and check all connections to ensure
that they are secure.Important: ensure that the voltage rating on the appliance suits the power supply to be
used and the correct type of plug fitted.
DO NOT pull or carry the appliance by the power cable.
8
DO NOT pull the plug from the socket by the cable. Remove the plug from the socket by maintaining a firm
8
grip on the plug.
DO NOT use worn or damaged cables, plugs or connectors. ensure that any faulty item is repaired or
8
replaced immediately by a qualified electrician.
1.0.3.
if the cable or plug is damaged during use, switch the off electricity supply and remove from use.
1.0.4.
this product requires an electrical supply in excess of 13 amps, and no plug is fitted.
You must therefore contact a qualified electrician to ensure that a 16 amp supply is available.
We recommend that you discuss the installation of a industrial round pin plug and socket with your electrician.
ensure that the unit is correctly earthed via a three-pin plug, as shown.
a) connect the green/yellow earth wire to the earth terminal
b) connect the brown live wire to live terminal 'l'.
c) connect the blue neutral wire to the neutral terminal, 'n' or unmarked.
d) After wiring, check that there are no bare wires, that all wires have been correctly connected,
that the external insulation extends beyond the cable restraint and that the restraint is tight.
Sealey recommend that repairs are carried out by a qualified electrician.
"Modern vehicles contain extensive electronic systems.You are required to check with the vehicle Manufacturer, for any specific
instructions regarding the use of this type of equipment on each vehicle."
"no liability will be accepted for damage / injury, where this product is not used in accordance with all instructions."
DANGER! BE AWARE, LEAD-ACID BATTERIES GENERATE EXPLOSIVE GASES DURING NORMAL BATTERY OPERATION.
FOR THIS REASON, IT VERY IMPORTANT TO READ AND FOLLOW THESE INSTRUCTIONS CAREFULLY, EACH TIME YOU USE
THE CHARGING EQUIPMENT.
1.0.5.
follow these instructions and those published by the battery and vehicle manufacturers, and the maker of any equipment you intend to
use in the vicinity of the battery. remember to review warning marks on all products and on engines.
WARNING! modern vehicles contain extensive electronic systems.
You are required to check with the vehicle Manufacturer, for any specific instructions regarding the use of this type of equipment on
each vehicle.
1.0.6.
no liability will be accepted for damage / injury, where this product is not used in accordance with all instructions.
Personal Precautions
1.1.
ensure there is another person within hearing range of your voice and close enough to come to your aid,
9
should a problem arise when working near a lead-acid battery.
Wear safety eye protection and protective clothing. Avoid touching eyes while working near battery.
9
Have fresh water and soap nearby in case battery acid contacts skin, clothing or eyes.
9
© Jack sealey limited
instructions for
STARTER/CHARGER 300AMP,400AMP,500AMP
12/24V
model no:
400.V2/SUPERSTART500.
Wear eye
Warning:
Protection
corrosive
substance
Original Language Version
SUPERSTART300.V5/SUPERSTART
Wear
Warning:
Protective
electricity
Gloves
suPerstArt300.v5,400.v2,500. | issue (1) 05/07/16
Protect
use in
Keep away
from
Well
from sources
rain
ventilated
of ignition:
Areas
battery could
explode
it is recommended
that the supply to this
product is fitted with a
16AmP fuse or breaker

Advertisement

loading

Summary of Contents for Sealey SUPERSTART300.V5

  • Page 1 400.V2/SUPERSTART500. Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble free performance. IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED.
  • Page 2 Model No: ..... . SUPERSTART300.V5......SUPERSTART400.V2......SUPERSTART500 output: ......12-24v..........12/24v..........12/24v output charge Peak (en): .
  • Page 3 Panel fig.3 4.4. Charging the Battery 4.4.1. Position the current adjustment diverters according to the capacity of battery to charge: fig.4 Original Language Version suPerstArt300.v5,400.v2,500. | issue (1) 05/07/16 © Jack sealey limited...
  • Page 4 Allow the unit to cool down, establish the reason for failure and correct. 5.2.3. replace the fuse. use only sealey replacement fuses. DO NOT use a fuse with copper bridges or similar as these will damage your equipment. We recommend you hold 2 or 3 spare fuses with the starter/charger.