Safety Notes
Explanation of symbols
General hazard safety alert.
Never direct the water jet
at people, animals, the
unit or electric compo-
nents.
Warning: High pressure jets can be dan-
gerous if subject to misuse.
According to the applicable
regulations, the appliance
must never be used on the
drinking water network without a
system separator. Use a separator as
per IEC 61770 Type BA.
Water flowing though a system sepa-
rator is considered not drinkable.
The AdvancedAquatak 150 is in-
tended for use only in premises
≥100 A
having a service current capacity
≥100 A per phase, supplied from a dis-
tribution network having a nominal volt-
age of 230 V. If in doubt please contact
your Supply Authority.
Safety Notes for pressure washer
Read all safety warnings and
all instructions. Failure to fol-
low the warnings and instruc-
tions may result in electric shock, fire
and/or serious injury.
The warning and information signs
attached to the unit provide impor-
tant information for safe operation.
Bosch Power Tools
Apart from the information in the op-
erating instructions comply with the
general safety regulations and regu-
lations for the prevention of acci-
dents.
Connecting to the mains
The voltage indicated on the rating
plate must correspond to the voltage
of the power source.
We recommend that this equipment
is only connected into a socket which
is protected by a circuit-breaker that
would be actuated by a 30 mA residu-
al current.
Remove the plug from socket when-
ever the machine is left unattended
for any period.
The electric supply installation
should comply with IEC 60364-1.
If the supply cord is damaged, it must
be replaced by the manufacturer, its
service agent or similarly qualified
persons in order to avoid a hazard.
If the plug is damaged, pay attention
to the following:
Plugs and sockets situated near the
work site or outdoors should be to
class IP 55 of BS 5490 to provide ad-
equate protection against ingress of
water, etc. and cable entries require
effective sealing. Rubber shrouds
should be provided over cable
glands. Drip-proof (class IP X2 of
BS 5490) plugs and sockets to
BS 4343 are suitable for use indoors
where the plug is away from the water
spray area where the appliance is in
use.