ABB ACS355 Supplement Manual page 18

High speed program (+n826)
Hide thumbs Also See for ACS355:
Table of Contents

Advertisement

18 Actual signals and parameters
All parameters
No.
Name/Value
0.0...1400.0 Hz
/ 0...32000 rpm
1205 CONST
SPEED 4
0.0...1400.0 Hz
/ 0...32000 rpm
1206 CONST
SPEED 5
0.0...1400.0 Hz
/ 0...32000 rpm
1207 CONST
SPEED 6
0.0...1400.0 Hz
/ 0...32000 rpm
1208 CONST
SPEED 7
0.0...1400.0 Hz
/ 0...32000 rpm
16 SYSTEM
CONTROLS
1605 USER PAR
SET CHG
Description
Speed in rpm. Output frequency in Hz if parameter 9904
MOTOR CTRL MODE setting is SCALAR: FREQ.
Defines constant speed (or drive output frequency) 4.
Speed in rpm. Output frequency in Hz if parameter 9904
MOTOR CTRL MODE setting is SCALAR: FREQ.
Defines constant speed (or drive output frequency) 5.
Speed in rpm. Output frequency in Hz if parameter 9904
MOTOR CTRL MODE setting is SCALAR: FREQ.
Defines constant speed (or drive output frequency) 6.
Speed in rpm. Output frequency in Hz if parameter 9904
MOTOR CTRL MODE setting is SCALAR: FREQ. Constant
speed 6 is used also as jogging speed.
Defines constant speed (or drive output frequency) 7.
Constant speed 7 is used also as jogging speed or with fault
functions (3001 AI<MIN FUNCTION and 3002 PANEL
COMM ERR).
Speed in rpm. Output frequency in Hz if parameter 9904
MOTOR CTRL MODE setting is SCALAR: FREQ. Constant
speed 7 is used also as jogging speed.
Parameter view, Run enable, parameter lock etc.
Enables the change of the User parameter set through a
digital input. See parameter
change is only allowed when the drive is stopped. During
the change, the drive will not start.
Note: Always save the User parameter set with parameter
9902
after changing any parameter setting, or reperforming
the motor identification. The last settings saved by the user
are loaded into use whenever the power is switched off and
on again or the parameter
unsaved changes will be lost.
Note: The value of this parameter is not included in the
User parameter sets. A setting once made remains despite
User parameter set change.
Note: Selection of User parameter set 2 can be supervised
through relay outputs RO 1...4 and digital output DO. See
parameters 1401 RELAY OUTPUT 1 ... 1403 RELAY
OUTPUT 3, 1410 RELAY OUTPUT 4 and 1805 DO
SIGNAL.
9902 APPLIC
MACRO. The
9902
setting is changed. Any
Def/FbEq
1 = 0.1 Hz
/ 1 rpm
E: 20.0 Hz
U: 24.0 Hz
1 = 0.1 Hz
/ 1 rpm
E: 25.0 Hz
U: 30.0 Hz
1 = 0.1 Hz
/ 1 rpm
E: 40.0 Hz
U: 48.0 Hz
1 = 0.1 Hz
/ 1 rpm
E: 50.0 Hz
U: 60.0 Hz
1 = 0.1 Hz
/ 1 rpm
NOT SEL