Mitsubishi Electric PUHZ-W50VHA Service Manual page 96

Split-type, air to water heat pump r410a
Hide thumbs Also See for PUHZ-W50VHA:
Table of Contents

Advertisement

PUHZ-HW112YHA(-BS)
PUHZ-HW112YHA2(-BS)
PUHZ-HW112YHA2R1(-BS)
PUHZ-HW112YHA2R3(-BS)
PUHZ-HW112YHA2R4(-BS)
PUHZ-HW112YHA2R5(-BS)
PUHZ-HW112YHA2R6(-BS)
PUHZ-HW112YHA2R7(-BS)
Switch
Function
Mark
No.
1
Manual defrost
To clear error
2
history
3
No function
SW1
4
Abnormal disregard
5
No function
6
No function
*2
SW4
1-2
No function
1
Silent setting (FAN)
2
Silent setting (Hz)
3
No function
SW5
4
No function
Defrost control
5
selection
6
No function
1-3
Model Setting
SW6
Single phase/
4
3 phase
5-8
Model Setting 2
1
Starting Ambient
temp. of blink
SW7
injection
*3
(HW·HA2)
2
3-6
No function
1
Mode selection
2
Max. current setting
SW8
Separate Interface/
Flow temp. controller-
3
outdoor unit power
supplies
SW9
1-4
No function
<Important Note>
All these DIP switches on PUHZ-HW·HA(2) are set as shown above.
Spare PCBs, however, will be supplied without any settings, which means that all Dip switches are switched OFF.
When servicing, please make sure to set all switches correctly, referring to the previous PCB which is removed from the unit.
*1
Manual defrost should be done as follows.
1 Change the DIP SW1-1 on the outdoor controller board from OFF to ON.
2 Manual defrost will start by the above operation 1 if these conditions written below are satisfied.
• Heat mode setting
• 10 minutes have passed since compressor starts operating or previous manual defrost is finished.
• Pipe temperature is less than or equal to 8:.
Manual defrost will finish if certain conditions have been satisfied.
Manual defrost can be done if above conditions have been satisfied when DIP SW1-1 is changed from OFF to ON.
After DIP SW1-1 is changed from OFF to ON, there is no problem if DIP SW1-1 is left ON or changed to OFF again.
This depends on the service conditions.
*2
Only PUHZ-HW·HA2R6/R7 mounts SW4.
*3
Only PUHZ-HW·HA2 mounts SW7.
OCH439M
PUHZ-HW140VHA(-BS)
PUHZ-HW140VHA2(-BS)
PUHZ-HW140VHA2R1(-BS)
PUHZ-HW140VHA2R2-BS
PUHZ-HW140VHA2R3(-BS)
PUHZ-HW140VHA2R4(-BS)
PUHZ-HW140VHA2R5(-BS)
PUHZ-HW140VHA2R6(-BS)
PUHZ-HW140VHA2R7(-BS)
Selection
ON (with)
OFF (without)
ON to start
usual setting
ON to clear
usual setting
Disregard
Normal
Silent setting (FAN)
usual setting
Silent setting (Hz)
usual setting
For high humidity
Standard
SW6
Model
1
2
HW•HA
0
0
HW•HA2
1
0
HW•HA2R3/R4
1
1
HW•HA2R5/R6/R7
0
1
1=ON, 0=OFF
3 phase
Single phase
SW6
Model
5
6
7
HW112
0
1
1
HW140
1
1
1
1=ON, 0=OFF
Ambient temp. of ZUBADAN Flash
injection becomes effective.
SW7-1 SW7-2
Ambient temp.
OFF
OFF
[ 3°C (Initial setting)
OFF
ON
[ 0°C
ON
OFF
[ -3°C
ON
ON
[ −6°C
Energy saving mode
Powerful mode
Max. current
Model
OFF
HW140V
35 A
HW140VHA2R1
31A
HW112/140Y
13 A
Separate power
Outdoor unit power
supply
supply
Default setting
OFF
Switch ON to force defrosting
Switch ON to clear (erase) the following status:
OFF
(1)Check codes and Suspension flags in RAM
(2)Check codes and Suspension flags in EEPROM
OFF
Check code (P8,UH):
OFF
Abnormal detection disregard
OFF
OFF
OFF
OFF
Fan speed setting in silent mode
OFF
Hz setting in silent mode
OFF
OFF
Switches to optimal defrosting operation for low-
OFF
temperature and high-humidity regions.
OFF
3
0
As shown in
0
the left table
0
1
HW112/140Y: ON
HW140V: OFF
8
As shown in
Make sure to set
0
the left table
SW6-5 to 8 correctly
0
OFF
OFF
OFF
OFF
ON
29.5 A
OFF
29.5A
12 A
OFF
Power supply connection method selection
96
PUHZ-HW140YHA(-BS)
PUHZ-HW140YHA2(-BS)
PUHZ-HW140YHA2R1(-BS)
PUHZ-HW140YHA2R3(-BS)
PUHZ-HW140YHA2R4(-BS)
PUHZ-HW140YHA2R5(-BS)
PUHZ-HW140YHA2R6(-BS)
PUHZ-HW140YHA2R7(-BS)
Function details
Effective
timing
*1
Always
Always
Always
Always
Always
Always
When power
supply ON
When power
supply ON