Siemens SIMATIC PCS 7 System Manual

Process control system, what's new in v8.0
Hide thumbs Also See for SIMATIC PCS 7:

Advertisement

SIMATIC
Process Control System PCS 7
What's new in SIMATIC PCS 7
(V8.0)?
System Manual
12/2011
A5E02779862-01
What's new in SIMATIC PCS
7 V8.0 compared to V7.1?
Engineering Station - What's
new in PCS 7 V8.0?
Operator Station - What's
new in PCS 7 V8.0?
SIMATIC BATCH - What's
new in SIMATIC BATCH
V8.0?
SIMATIC Route Control -
What's new in SIMATIC
Route Control V8.0?
SIMATIC PDM - What's new
in PDM V8.0?
Process Historian - What's
new?
Documentation - What's
new?
1
2
3
4
5
6
7
8

Advertisement

Table of Contents
loading

Summary of Contents for Siemens SIMATIC PCS 7

  • Page 1 PCS 7 V8.0? SIMATIC SIMATIC BATCH - What's new in SIMATIC BATCH V8.0? Process Control System PCS 7 What's new in SIMATIC PCS 7 SIMATIC Route Control - (V8.0)? What's new in SIMATIC Route Control V8.0? SIMATIC PDM - What's new System Manual in PDM V8.0?
  • Page 2 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 3: Table Of Contents

    Table of contents What's new in SIMATIC PCS 7 V8.0 compared to V7.1?................5 Engineering Station - What's new in PCS 7 V8.0?..................7 CFC - Engineering What's new in CFC V8.0?................7 PO - What's new in PO V8.0?.......................8 PH - What's new in PH V8.0?......................8 APL - What's new in the Advanced Process Library V8.0?............8...
  • Page 5: What's New In Simatic Pcs 7 V8.0 Compared To V7.1

    What's new in SIMATIC PCS 7 V8.0 compared to V7.1? The following paragraphs provide an overview of the most important functional enhancements and expansions in SIMATIC PCS 7 V8.0 compared to SIMATIC PCS 7 as of V7.1. Overview of highlights ● Operating system SIMATIC PCS 7 V8.0 runs on the following operating systems:...
  • Page 6 ● Fault-tolerant ● PC-based PCS 7 mEC RTX are available as of SIMATIC PCS 7 V8.0 as additional automation systems. A number of centrally connected IO modules are also supported with PCS 7 mEC RTX. These features provide a cost-effective solution for small-scale applications and distributed control systems.
  • Page 7: Engineering Station - What's New In Pcs 7 V8.0

    – Several instances can now be created from a location type – There are now standard location types with fixed names – A range of numbers for locations can be specified in the project What's new in SIMATIC PCS 7 (V8.0)? System Manual, 12/2011, A5E02779862-01...
  • Page 8: Po - What's New In Po V8.0

    CntOhSc Combined block for recording operating hours and start-up events. RealToDw Block for converting a REAL number into a double word. FbDrive Channel block for compact drives FbSwtMMS What's new in SIMATIC PCS 7 (V8.0)? System Manual, 12/2011, A5E02779862-01...
  • Page 9 The MotSpdCL block determines the machine and motor speed using a gear reduction factor. RateLim Extension of the RateLim ramp block by the "Ramp-shaped approach to a target value" function. What's new in SIMATIC PCS 7 (V8.0)? System Manual, 12/2011, A5E02779862-01...
  • Page 10: Apl - What's New In The Advanced Process Faceplates V8.0

    ● Double coding of the icons for valves (rotation of the single valve icon or cross lines for a two-way valve) ● Motors with motor signs or arrows in different directions What's new in SIMATIC PCS 7 (V8.0)? System Manual, 12/2011, A5E02779862-01...
  • Page 11: Basic Library - What's New In The Basic Library V8.0

    Basic Library - What's new in the Basic Library V8.0? New blocks in Basic Library V8.0 MOD_DRV System block for the connection of compact drives. MOD_SWT System block MOD_SWT for the connection of motor management starters What's new in SIMATIC PCS 7 (V8.0)? System Manual, 12/2011, A5E02779862-01...
  • Page 12 ● The PADP_L10, MOD_PAX0, MOD_PAL0 system blocks have been extended to 32 channels. ● Flutter suppression for OB82 and OB83 events ● Support for new hardware: – S7_mEC – S7-400 STD. CPU V6 What's new in SIMATIC PCS 7 (V8.0)? System Manual, 12/2011, A5E02779862-01...
  • Page 13: Operator Station - What's New In Pcs 7 V8.0

    – Web Client V8.0 can be connected to Web Server V7.1 – "Load balancing" functionality for automatic distribution of Web clients to Web servers. – Terminal server and Web server can be on a single computer What's new in SIMATIC PCS 7 (V8.0)? System Manual, 12/2011, A5E02779862-01...
  • Page 15: Simatic Batch - What's New In Simatic Batch V8.0

    Windows XP" or "MS Windows 7" independent of the server operating system. – In SIMATIC PCS 7 V8.0, the Common Archive Server (CAS) has been replaced by the new Process Historian (PH). SIMATIC BATCH can archive batch data on a PH and perform revision archiving.
  • Page 16 You can now visualize information about a selected item in a preview window before you make your selection. The preview window shows the master recipe and another window displays the name, type, status, product and properties. What's new in SIMATIC PCS 7 (V8.0)? System Manual, 12/2011, A5E02779862-01...
  • Page 17 Using this function from the View menu in BatchCC and in the recipe editor, you can pin the information of the units when scrolling through large control recipes and master recipes. What's new in SIMATIC PCS 7 (V8.0)? System Manual, 12/2011, A5E02779862-01...
  • Page 18 PCell. Activating a report via SIMATIC BATCH API A new function allows you to activate recipe and batch logs via an SB API. What's new in SIMATIC PCS 7 (V8.0)? System Manual, 12/2011, A5E02779862-01...
  • Page 19: Simatic Route Control - What's New In Simatic Route Control V8.0

    The RC_ResPosV5 compatibility block provides the behavior of V5 at the QRESTPOS output at RC_IF_ROUTE (FB 800). Opening the Route Control server dialog You can open the Route Control server dialog by running rc_serverdialog.exe with the following parameters: What's new in SIMATIC PCS 7 (V8.0)? System Manual, 12/2011, A5E02779862-01...
  • Page 20 ● /NoDiaolg The server dialog closes after it is called - no dialog The way the parameters are stipulated depends on the particular implementation of the launch and must be solved for the specific user. What's new in SIMATIC PCS 7 (V8.0)? System Manual, 12/2011, A5E02779862-01...
  • Page 21: Simatic Pdm - What's New In Pdm V8.0

    Modified license structure A new license called "SIMATIC PDM extended" is being introduced. You can use the following additional functions with this option: ● Import ● Export What's new in SIMATIC PCS 7 (V8.0)? System Manual, 12/2011, A5E02779862-01...
  • Page 22 ● History trend saved as a CSV file so that it can be edited further using an application such as EXCEL ● Ruler position displayed ● Zoom functions can be accessed via buttons What's new in SIMATIC PCS 7 (V8.0)? System Manual, 12/2011, A5E02779862-01...
  • Page 23 Field devices that are deleted in HW Config or in the Process Device Network View are now removed from the Process Device Plant View as well. It is no longer necessary to remove them manually. What's new in SIMATIC PCS 7 (V8.0)? System Manual, 12/2011, A5E02779862-01...
  • Page 25: Process Historian - What's New

    Process Historian does not need a connection to the plant bus. It can be connected to the OS and Batch Servers of the SIMATIC PCS 7 plant via terminal bus, for example, using the integrated network connection (on-board Ethernet RJ45 port) of the server.
  • Page 26 ● Creation of Excel reports for historical process values and messages, as well as the storage of Excel report templates on the Information Server ● Support of subscriptions for Excel report templates What's new in SIMATIC PCS 7 (V8.0)? System Manual, 12/2011, A5E02779862-01...
  • Page 27: Documentation - What's New

    ● PCS 7 Compendium, Part D ● PCS 7 APL Operator Guide ● PCS 7 APL Style Guide ● Maintenance Station Manual ● Manual on licenses & quantity frameworks What's new in SIMATIC PCS 7 (V8.0)? System Manual, 12/2011, A5E02779862-01...

Table of Contents