ETSI environmental and CRoHS guidelines

2.3 Other environmental requirements

Observe the following environmental requirements when handling Nokia FastMile
Outdoor Unit equipment.
2.3.1
See chapter
Nokia FastMile Outdoor Unit equipment and other Nokia FastMile Outdoor Unit
specifications.
2.3.2
According to ETS 300-019-1-1 - Class 1.1, storage of Nokia FastMile Outdoor Unit
equipment must be in Class 1.1, weather-protected, temperature-controlled
locations.
2.3.3
According to EN 300-019-1-2 - Class 2.3, transportation of Nokia FastMile Outdoor
Unit equipment must be in packed, public transportation.
2.3.4
According to EN 300-019-1-3 - Class 3.1/3.2/3.E, stationary use of Nokia FastMile
Outdoor Unit equipment must be in a temperature-controlled location, with no rain
allowed, and with no condensation allowed.
2.3.5
The thermal limitations for the Nokia FastMile Outdoor Unit equipment are:
11

Environmental requirements

9
in this guide for more information about temperature ranges for the

Storage

Transportation

Stationary use

Thermal limitations

operating temperature (ambient): –30°C to 65°C (–22°F to 149°F)
operating relative humidity: 5% to 85% relative humidity, non-condensing
short-term relative humidity: 5% to 93% relative humidity, non-condensing