Cisco PowerVu D9858 Installation And Operation Manual page 155

Advanced receiver transcoder
Hide thumbs Also See for PowerVu D9858:
Table of Contents

Advertisement

Warning
FPGATemperature
Warning
TDT timeout
SDT timeout
PMT timeout
4023074 Rev B
Model D9858 Advanced Receiver Transcoder Installation and Operation Guide
Message
Message
Type
Set
Temperature over
Warning threshold
Clear
Clear Temperature
Warning
Set
tdt timed out
tdt is lost
Clear
tdt fault cleared
Set
sdt # timed out
sdt # is lost
Clear
sdt fault cleared
Set
pmt # timed out
pmt # is lost
Clear
pmt fault cleared
Cause/Remedy
Cause: Room temperature
too high, or air flow is
blocked.
Remedy: Check openings
on front and rear panels for
blockage. Lower room
temperature or improve air
flow to device.
Cause: Uplink is not
sending or is sending
intermittently.
Remedy: Clear warning. If
problem persists determine
if uplink is sending the
current SI information
table. Disable the warning
if not using the table.
Cause: Uplink is not
sending or is sending
intermittently.
Remedy: Clear warning. If
problem persists determine
if uplink is sending the
current SI information
table. Disable the warning
if not using the table.
Cause: Uplink is not
sending or is sending
intermittently.
Remedy: Clear warning. If
problem persists determine
if uplink is sending the
current SI information
table. Disable the warning
if not using the table.
Description
FPGA temperature is
above normal
operating range.
Time Date Table was
never received.
No longer receiving
Time Date.
Service Description
Table was never
received.
No longer receiving
Service Description.
Program Mapping
Table was never
received.
No longer receiving
Program Mapping
Table.
5-15