Parameter set-up Torque open loop in Advanced Vector Control mode
Function
Basic Settings
Configuration Mode
Motor Control Principle
Torque PI control settings
Torque PI Proportional Gain
Torque PI Integration Time
Reference Handling (Nm) Reference 53; Limit 54
Reference range
Terminal 53 Low Voltage
Terminal 53 High Voltage
Terminal 53 Low Ref.
Terminal 53 High Ref
Speed Limit Factor Adjustable on input 54
Terminal 54 Low Voltage
Terminal 54 High Voltage
Terminal 54 Low Ref
Terminal 54 High Ref
8
166
Parameter
Setting
H-40
Torque Open Loop
H-41
Advanced Vector
PI-12
Default 100 %
PI-13
Default 0.02 sec
F-50
Min - max
AN-10
0V (Default 0.07V)
AN-11
10V
AN-14
0 Nm
AN-15
Max torque on motor shaft
AN-20
0V (default 0.07V)
AN-21
10 V
AN-24
0V
AN-25
1500 rpm (adjustable setting)