fig.6
5.4.
Move the panel dryer into position, approximately 500mm (20 inches from the area to be heated.
5.5.
Adjust cassette heads around the contours of the repair area and lock into position.
WARNING! Always ensure the cassette cables are NOT in front of the cassettes during operation.
5.6.
Controller set up. See fig.6
Start with the Flash setting.
5.6.1.
5.6.1.1.
Press F button - display panel indicates SET: F- Time. Adjust the desired time up to 90 minutes using the Up or Down buttons.
5.6.1.2.
Press F button again, display panel indicates SET:F- Temp. Adjust the desired temperature using Up or Down buttons.
5.6.2.
Now to Bake setting See fig.7
5.6.2.1.
Press B button- display panel indicates SET: B- Time. Adjust the desired time up to 90 minutes using the Up or Down buttons.
5.6.2.2.
Press B button again, display panel indicates SET: B-Temp. Adjust the desired temperature using the Up or Down buttons.
5.7.
To start.
5.7.1.
Press S (Start) button. This enters your pre-set Flash settings mode. The display will read as per example Fig.7.
5.7.2.
The % Power defaults to 50% in Flash mode. This can be adjusted using the Up or Down buttons.
Note: this can only be adjusted when the program is running.