  • Page 2 The user is responsible for all changes and repairs made to the device by the user or the user’s agent.  All new components are to be provided by Siemens Milltronics Process Instruments.  Restrict repair to faulty components only.
  • Page 3 ___________________ SITRANS WF100 Introduction ___________________ Safety notes ___________________ Description SITRANS ___________________ Installing/Mounting Flowmeters ___________________ SITRANS WF100 Connecting ___________________ Commissioning Operating Instructions ___________________ Service and maintenance ___________________ Technical data ___________________ Dimension drawings 7MH7186 02/2012 7ML19985NB01-01...
  • Page 4 Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems.
  • Page 5: Table Of Contents

    Installation in hazardous areas ....................7 Description ...........................9 Material feed examples ......................14 Installing/Mounting........................21 Connecting ..........................25 Commissioning ........................... 27 Service and maintenance ......................31 Technical data ..........................37 Dimension drawings ........................41 SITRANS WF100 Operating Instructions, 02/2012, 7ML19985NB01-01...
  • Page 6 Table of contents SITRANS WF100 Operating Instructions, 02/2012, 7ML19985NB01-01...
  • Page 7: Introduction

    Introduction Note The Siemens flowmeter system is to be used only in the manner outlined in these operating instructions, otherwise protection provided by equipment may be impaired. • It is your responsibility to read these operating instructions before installing and starting up any component of the system to which the flowmeter is being applied.
  • Page 8 Introduction SITRANS WF100 Operating Instructions, 02/2012, 7ML19985NB01-01...
  • Page 9: Safety Notes

    Alterations to the product, including opening or improper repairs of the product, are not permitted. If this requirement is not observed, the CE mark and the manufacturer's warranty will expire. Installation in hazardous areas SITRANS WF100 SOLIDS FLOWMETER 7MHxxxx-xxxxx-xxxx-x Serial #: GYZ / A1034567 Input: 15 V...
  • Page 10 The flowmeter construction materials include: mild steel (polyester power coat painted) or stainless steel, nonurethane encapsulant, and silicone rubber seals. 11. Product marking shall include the warning: Do not disassemble when an explosive dust atmosphere is present. SITRANS WF100 Operating Instructions, 02/2012, 7ML19985NB01-01...
  • Page 11: Description

    Description SITRANS WF100 flowmeter is a low- to medium-capacity flowmeter for various product sizes, densities, and fluidities in restricted spaces. This compact unit improves processing, increases operating efficiency, and helps provide significant cost savings. Operating with a microprocessor-based Siemens integrator, the Milltronics SF500 displays flowrate, totalized flow, and alarms.
  • Page 12 Description Components Siemens flowmeters react to the horizontal component of force created by the impact of material on the sensing plate. Siemens flowmeters consist of two physical components: ● the housing which includes the flowguide and the outlet: supports the sensing assembly and guides the material flow ●...
  • Page 13 The displacement of the load cell is sensed by its strain gauges. These convert the excitation signal from the electronic integrator to produce a signal proportional to material flow. ① Positive stop ② Negative stop SITRANS WF100 Operating Instructions, 02/2012, 7ML19985NB01-01...
  • Page 14 -5 to 0 mV DC. ① Negative displacement ① Normal gap Applications Note For best performance and limited maintenance requirements, keep in mind material compatability and flow patterns. SITRANS WF100 Operating Instructions, 02/2012, 7ML19985NB01-01...
  • Page 15 Linings ● Sensing plate abrasion resistant linings are often used for aggregates, barley, corn, soybeans, wheat, and material with similar hardness and particle mass. Abrasive materials are best monitored at low velocity. SITRANS WF100 Operating Instructions, 02/2012, 7ML19985NB01-01...
  • Page 16: Material Feed Examples

    • commonly used for grain applications • feeder discharge damping required when slow elevators (typically chain drive) produce heavily pulsing material discharge • use deadbox if required to reduce material velocity from fast elevators (typically re-inforced belt drive) SITRANS WF100 Operating Instructions, 02/2012, 7ML19985NB01-01...
  • Page 17 Vibratory feeder • produces a non-pulsing material discharge • use reverse flowguide transition for variable speed varieties ① motor ② vibrating pan SITRANS WF100 Operating Instructions, 02/2012, 7ML19985NB01-01...
  • Page 18 • material velocity due to gravity minimized • chute centreline and angle should coincide with that of the flowguide, for a distance greater than or equal to the flowguide diameter (before the flowguide inlet) ① < 0.6 m (2 ft) SITRANS WF100 Operating Instructions, 02/2012, 7ML19985NB01-01...
  • Page 19 • installed where the chute angle changes. This will cause the material to impact upon itself, rather than the chute surface. • used when the feeder discharge velocity is high, variable, where long fall chute angles change, and if the material is particularly abrasive SITRANS WF100 Operating Instructions, 02/2012, 7ML19985NB01-01...
  • Page 20 • A tuning gate can be installed in each vent to balance the air pressure. • If a dust collector is not used, an air bypass chute can be installed between the flowmeter in-feed and discharge chutes. ① to common dust collector SITRANS WF100 Operating Instructions, 02/2012, 7ML19985NB01-01...
  • Page 21 Refer to the following chart to ensure the flowguide capacity is suitable. 2.56 2.24 4" 6" 8" 10" 1.92 100mm 150mm 200mm 250mm 1.60 1.28 0.96 0.64 0.32 Figure 3-1 Flowguide capacity chart SITRANS WF100 Operating Instructions, 02/2012, 7ML19985NB01-01...
  • Page 22 Description 3.1 Material feed examples SITRANS WF100 Operating Instructions, 02/2012, 7ML19985NB01-01...
  • Page 23: Installing/Mounting

    Preparation Prepare the site in accordance to the Siemens Milltronics installation drawing(s) that are available for download from our website: Siemens weighing (http://www.siemens.com/weighing). If there is confusion or doubt to do with the installation, please consult your Siemens representative. CAUTION When unpacking the flowmeter, avoid subjecting the unit to mechanical shock.
  • Page 24 1. Set the flowmeter housing in place ensuring that the flowguide and outlet gaskets are correctly located (gaskets supplied by customer). 2. The housing must be vertical within 1° in two planes 90° apart. 3. Bolt the flowguide and outlet flanges to the process piping. SITRANS WF100 Operating Instructions, 02/2012, 7ML19985NB01-01...
  • Page 25 The hole in the enclosure for the shipping stop should be plugged with a bolt or cap to ensure a dust-tight seal. 5. Connect the unit to the integrator 90º ① Infeed (customer supplied) ② Mounting hardware ③ Gasket ④ SITRANS WF100 ⑤ Discharge (customer supplied) ⑥ Calibration pulley SITRANS WF100 Operating Instructions, 02/2012, 7ML19985NB01-01...
  • Page 26 Installing/Mounting SITRANS WF100 Operating Instructions, 02/2012, 7ML19985NB01-01...
  • Page 27: Connecting

    Connecting SITRANS WF100 wiring ① Load cell ② Conduit and box connector (not provided on hazardous option) ③ Customer junction box Load cell Milltronics integrator SIWAREX FTC + EXC + EXC - EXC - EXC - SIG 'A' - SIG...
  • Page 28 Connecting SITRANS WF100 Operating Instructions, 02/2012, 7ML19985NB01-01...
  • Page 29: Commissioning

    Refer to the integrator instruction manual for programming and calibration details and for information about material tests. All operating instructions are available for download from our website: Siemens weighing (http://www.siemens.com/weighing) Test rate The test rate is the material flowrate represented by the test weight. The test weight is used to simulate the horizontal forces of the material hitting the sensing plate.
  • Page 30 1. Install the calibration pulley to the bracket on the flowmeter housing. 2. Hang the test weight over the calibration pulley using the test weight cable. 3. Perform the span calibration as described in the calibration section of the integrator instruction manual. SITRANS WF100 Operating Instructions, 02/2012, 7ML19985NB01-01...
  • Page 31 At least two 5 minute samples should be taken to ensure repeatability. Refer to material test and subsequent factoring of the flowmeter sections of the integrator manual. Re-rating Consult your local Siemens Milltronics representitive for re-rating. SITRANS WF100 Operating Instructions, 02/2012, 7ML19985NB01-01...
  • Page 32 Commissioning SITRANS WF100 Operating Instructions, 02/2012, 7ML19985NB01-01...
  • Page 33: Service And Maintenance

    WARNING Do not strike the flowmeter, its components, or adjacent piping to dislodge material. Check for wearing of the sensing plate. If wear is excessive contact your Siemens Milltronics representative. SITRANS WF100 Operating Instructions, 02/2012, 7ML19985NB01-01...
  • Page 34 The following are the recommended spare parts. As each may be available in more than one option, consult Siemens Milltronics for assistance in ordering spare parts. In all correspondence please quote the serial number of the unit for which the parts are required.
  • Page 35 While transporting, support the load cell/sensing plate assembly as shown in Load cell handling. ① Load cell cable ② Load cell mounting screws ③ Shipping stop ④ Sensing plate Figure 7-1 Enclosure door removed for clarity SITRANS WF100 Operating Instructions, 02/2012, 7ML19985NB01-01...
  • Page 36 1. With the sensing plate resting in its static position, insert shipping bolt as shown. 2. Tighten the nut against the housing to secure the bolt in place. ① Sensing plate ② Washer ③ Shipping stop ④ ⑤ SITRANS WF100 housing SITRANS WF100 Operating Instructions, 02/2012, 7ML19985NB01-01...
  • Page 37 Please note the following: ● The user is responsible for all changes and repairs made to the device. ● All new components must be provided by the Siemens Milltronics Process Instruments Inc. ● Only repair faulty components.
  • Page 38 Service and maintenance Additional Support Please contact your local Siemens representative and offices if you have additional questions about the device Find your contact partner at: Local contact person (http://www.siemens.com/automation/partner) SITRANS WF100 Operating Instructions, 02/2012, 7ML19985NB01-01...
  • Page 39: Technical Data

    -40 to 75ºC (-40 to 167ºF) operating range -18 to 65ºC (0 to 150ºF) compensated Nominal sizes 100, 150, 200, 250 mm (4, 6, 8, 10") Flow rate 3 to 200 t/h (4 to 220 STPH) SITRANS WF100 Operating Instructions, 02/2012, 7ML19985NB01-01...
  • Page 40 304 (1.4301) or 316 (1.4404) stainless steel gasketing FDA approved silicone sensing plate 304 (1.4301) stainless steel optional: 316 (1.4404) stainless steel, wear resistant coatings, low friction coating SITRANS WF100 Operating Instructions, 02/2012, 7ML19985NB01-01...
  • Page 41 CSA/FM Class II, Div. 1, Groups E,F,G and Class Europe ATEX II 2D Ex tb IIIC T80°C Db IP65 International IECEx Ex tb IIIC T80°C Db IP65 Stainless steel options meet FDA and USDA requirements for food processing Australia C-TICK SITRANS WF100 Operating Instructions, 02/2012, 7ML19985NB01-01...
  • Page 42 Technical data SITRANS WF100 Operating Instructions, 02/2012, 7ML19985NB01-01...
  • Page 43: Dimension Drawings

    Dimension drawings 60° Figure 9-1 SITRANS WF100 dimensions Size ① ② ③ ④ ⑤ ⑥ Flange ∅ (8 places) 4" 8 (203.2) 23.5 (596.9) 21.87 4 (100) ∅0.43 (11) 11.25 (555.5) (285.8) 6" 10 (254) 33 (838.2) 31.12 6 (150) ∅0.43 (11)
  • Page 44 Dimension drawings SITRANS WF100 Operating Instructions, 02/2012, 7ML19985NB01-01...
  • Page 45 For more information www.siemens.com/level www.siemens.com/weighing Siemens AG Subject to change without prior notice Industry Sector 7ML19985NB01 Rev.1.1 1954 Technology Drive © Siemens AG 2012 P.O. Box 4225 *7ml19985NB01* Peterborough, ON Canada K9J 7B1 email: techpubs.smpi@siemens.com Printed in Canada www.siemens.com/processautomation...