Bandwidth Sizing Guidelines; Emc Vnx - Dell EMC Series Server Sizing Manual

Surveillance storage with iss securos
Table of Contents

Advertisement

Sizing the solution

Bandwidth sizing guidelines

EMC VNX

Dell EMC Storage with ISS SecurOS Sizing Guide
18
All solution tests were performed in a lab environment. The storage system, cameras,
and VLANs in the lab environment were dedicated to these tests.
Connections to the storage system under test conditions were restricted to SecurOS
Video Server, monitoring, and web management stations. Expect some variance
between the lab results and a production environment.
We conducted validation tests to determine how ISS works with VNX storage arrays.
The test results shown in the following table are based on a conservative model to
ensure that the constant-bandwidth video traffic is unaffected during a single storage
pool (SP) maintenance cycle, disk rebuild, or similar performance-intensive events.
The VNX 5300 and VNX-VSS100 can exceed 500 MB/s in an environment without
induced errors.
Table 2 EMC VNX/VNXe storage array results
Storage
Array
Protocol
iSCSI
VNX5300
VNX-
VSS100
VNX5200
* This bandwidth is the maximum tested per SP on the VNX system and not the array
maximum
Note
All disks are NL-SAS, 4 TB 7200 RPM drives unless otherwise stated.
The following table lists the firmware builds used in these tests. Expect equal or better
results if you use more recent firmware or newer models of VNX storage.
Table 3 EMC VNX firmware builds
Array
VNX5300
VNX5200
Bandwidth
Storage Pools
(MB/s)
Array/
LUN
Pools
Pool
60
60
1
60
60
1
60
60
1
300*
30
1
Firmware
VNX OE 5.32.000.5.206
VNX OE 5.33.000.5.035
RAID
LUNs/
Disks/
Pool
Pool
1
72
5
1
72
5
1
81
5
5
81
5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Emc vnx-vss100Emc vnx5300Emc vnx5200

Table of Contents