ABB M1M 10 Quick Start Manual page 2

Advertisement

Press Down key
Row 1: ----
18
Row 2: PWd
(Password
user definable).
CAUTION:
memorize the
Password.Use the same
Password for next time.
Instruments will reject
other Passwords.
19
Press DOWN key
Row 1: 4.000
Row 2: POLS
(POLES)
20
Press DOWN key
Row 1: 15.00
Row 2: voltage
suppression
21 Press DOWN key
Row 1: S A V E
Row 2: "Y"
blinking
22
Press DOWN key
Row 1 : xxxx
Row 2 : xxxx
Row 3 : xxxx
Once the required parameter is programmed press the DOWN key continuously till it
reaches SAVE page directly.
Default
Sl.No.
Parameter
setup
Connection mode(ELEm)
STAR/ DELTA/ 1.Phase
1
STAR
2
PT Primary (P.Prı)
415.0
100V- 999kV
3
PT Secondary (PT SEC)
415.0
50V - 550V
4
CT Primary (C.Prı)
5.000
0.5A - 99kA
5
CT Secondary (C.SEC)
5.000
0.5A - 6A
Password (PWd)
1000
6
1000 to 9999
No of Poles (POLES)
7
4.000
1.000 to 28.00
8
Voltage Suppression
15.00
10.00 to 80.00
8. MECHANICAL SPECIFICATION
90
52
90
M
1 M
1 0
96
96
9. TECHNICAL SPECIFICATION
Auxiliary power supply
Range
80V to 300 V AC or DC
Frequency
50 - 60Hz
Burden
5VA Max
Installation category
CAT III
Protection fuse
200mA
Measurement accuracy
Voltage
±1,0%
Current
±1,0%
Voltage measurement inputs
Measurement range
80-300V AC (p-n)
Measurement category
CAT III
Rated frequency
50 - 60Hz
Max. VT Primary
999 Kv
Burden
0.2VA Max. per phase
Current measurement inputs
Range: 1000-9999.
CAUTION: Password can
Number of current inputs
be reset only
CT secondary
at the factory.
Measurement range without
accuracy derating
Max. CT Primary
Burden
Range: 1-28 (FOR RPM).
User Interface
Access to device
Display type
Range: 10-80.
LED Digit height
Mechanical characteristics
If "n"(no) is selected then
Meter enters into RUN
Overall dimensions
mode without affecting any
edited Values in the setup
IP degree of protection
Weight
Climatic conditions
Operating temperature
Storage temperature
Relative humidity
Pollution degree
Altitude
Range / Options
Terminal characteristics
Current inputs
Voltage inputs
Standards
Electrical safety
EMC
Note:
Accuracy class note for current: For input current below 250mA, additional
error of 0.1% of full scale.
Accuracy class error for Temperature: Below 10 C, mean temperature
coefficient for the meter is 0.15%/K
+2
-0
+2
90
-0
90
3 (L1, L2, L3)
1A or 5A
50mA-6A (5%-120% as per standard.
From 50mA onwards, it will measure)
99 kA
0.2VA Max. per phase
2 pushbuttons
LED display
10 mm
96 X 96 X 58 mm (52 mm depth
inside the switchboard)
IP51 (IEC 60529)
0,300 kg
-10°C to +60°C
-25°C to +70°C
5% to 95% non condensing
2
Below 2000ms
6 terminals, 3 inputs, 5A with
S1 and s2 on each input
4 terminals. 80-520V LL
IEC 61010
IEC 61000 4-2,4-3,4-6,4-8,4-4,4-11,
CISPR-22
o