Chapter 5 System Configuration - Mitsubishi Electric MELSEC iQ-R RD78G4 User Manual

Motion module
Hide thumbs Also See for MELSEC iQ-R RD78G4:
Table of Contents

Advertisement

5
SYSTEM CONFIGURATION
CC-Link IE TSN is configured using Ethernet cables. (Page 40 Ethernet cable)
(5)
(4)
(1) Motion module
(2) Drive unit
(3) Inverter device
(4) Remote I/O module
(5) Ethernet device
Authentication Class setting
From "Connection Device Information" under "Basic Settings" of the engineering tool, select either of the following items
according to devices to be connected.
Connected device
information
Authentication Class B Only
Mixture of Authentication Class
B/A or Authentication Class A
Only
When connecting an authentication Class B device and an authentication Class A device, use a general-purpose hub.
(Page 40 Hub)
No.0
No.0: Master station of authentication Class B device
 Up to eight slave stations of authentication Class B devices can be connected.
 General-purpose hub (NZ2EHG-T8(N) or DT135TX)
(1), (2), (3): Ethernet device (such as personal computer, vision sensor, or bar code reader)
Modules can be connected in any order regardless of the station number.
No.0
(3)
System configuration
Select this if the system is to be configured without connecting the authentication Class A device.
• Page 30 Connection with modules on CC-Link IE TSN only
• Page 31 Connection with modules on CC-Link IE TSN and Ethernet devices
Select this if the system is to be configured in the future with the authentication Class A device
connected.
• Page 33 Connection with modules on CC-Link IE TSN and Ethernet devices
Ò
No.1
No.8
No.1
(1)
(2)
Ó
No.3
Switching hub
TSN hub
(authentication Class
B)
General-purpose hub
(authentication Class
A)
(2)
(1)
(3)
No.2
5 SYSTEM CONFIGURATION
5
29