Operating Instructions
All functions and parameters of the NOVA can be set and recalled on the display at the feed table.
Display indicator for:
1 Developer temperature
2 Fixer temperature
3 Dryer step
4 OK signal
5 SET - key
6 + key
7 - key
8 Value display
9 Status indication / Menu step
Setting the process parameters
- Use the (+) and (-) key to scroll the program
- Activate a process setting with the SET key, a dot will appear at the bottom richt side (9)
- The parameter value can now be changed using the (+) or (-) key
- After 10 sec or by pressing SET the changed value is saved
and the display returns to the DEV temperature indication function
Digital | Eddy Current | Film | Testing Machines | Ultrasonics | X-ray
8
9
1
2
3
4
5
6
7
Menu
Process parameter
1
Developer temperature
2
Fixer temperature
3
Dryer step
4
Process setting
5
Developer replenishment
6
Fixer replenishment
7
Water replenishment
*) The setting of the water feed rate is an optional feature which can only be made when using a Comfort Kit.
DEV
Developer temperature (°C)
FIX
DR Y
DEV
Fixer temperature (°C)
FIX
DRY
Dryer step
DEV
FIX
DRY
DEV
Process setting
FIX
DRY
DEV
Developer replenishment (x10 ml/m²)
FIX
DRY
DEV
Fixer replenishment (x10 ml/m²)
FIX
DRY
Water feed rate (l/m²)
DEV
FIX
DRY
Range
Standard settings
22 - 37 °C
28 °C
22 - 37 °C
28 °C
1 - 6
Step 4
1.5´ - 12´
200 - 950 ml/m²
900 ml/m²
500 - 1250 ml/m²
1200 ml/m²
0 - 15 l/m²
13 l/m² *)
Film

Advertisement

loading

Summary of Contents for GE NOVA

  • Page 1 Inspection Technologies Film NOVA Brief Instruction Card Operating Instructions All functions and parameters of the NOVA can be set and recalled on the display at the feed table. Display indicator for: Developer temperature (°C) DR Y 1 Developer temperature 2 Fixer temperature Fixer temperature (°C)
  • Page 2 - Insert 1 or 2 large sheets of cleaning film before processing the first actual exposure. As cleaning films, undeveloped Agfa NDT film should be used. - Regular maintenance will ensure optimal film results and extend the lifetime of the NOVA film processor. An authorized GE Inspection Technologies Service Technician best carries out major maintenance.