Thank you very much for purchasing Panasonic products. Please read this Instruction
Manual carefully and thoroughly for the correct and optimum use of this product.
Kindly keep this manual in a convenient place for quick reference.
Never use this product as a sensing device for personnel protection.
In case of using sensing devices for personnel protection, use prod-
ucts which meet laws and standards, such as OSHA, ANSI or IEC
WARNING
etc., for personnel protection applicable in each region or country.
For further details on the fiber sensor amplifier, please refer to 'Panasonic Electric
Works SUNX website (http://panasonic-electric-works.net/sunx)' or contact our office.
1
SPECIFICATIONS
Type
NPN output
Item
Model No.
FX-301-HS
Supply voltage
Normal operation: 960mW or less
Power consumption
ECO mode: 600mW or less
<NPN output type>
NPN open-collector transistor
Maximum sink current: 100mA (Note 1)
Applied voltage: 30V DC or less
Output
(between output and 0V)
Residual voltage: 1.5V or less
[at 100mA (Note 1) sink current]
Output operation
Light-ON or Dark-ON, selectable with jog switch
Short-circuit protection
H-SP: 35 s or less, FAST: 150 s or less, S-D: 250 s or less,
Response time
STD: 250 s or less, LONG: 2ms or less selectable with jog switch
Digital display
2-level teaching / Limit teaching / Full-auto teaching /
Sensitivity setting
Manual adjustment
Fine sensitivity
adjustment function
Incorporated with variable ON-delay / OFF-delay / ONE-SHOT timer,
Timer function
switchable either effective or ineffective (Timer: approx. 0.5 to 9999ms)
-10 to +55
Ambient temperature
if 8 to 16 units are connected in cascade: -10 to +45 )
(No dew condensation or icing allowed), Storage: -20 to +70
Ambient humidity
Emitting element
Enclosure: Heat-resistant ABS, Transparent cover: Polycarbonate
Material
Press switches: Acrylic, Jog switch: Heat-resistant ABS
Weight
Notes: 1)
50mA, if five, or more, amplifiers are connected in cascade.
2)
The cable for amplifier connection is not supplied as an accessory. Make sure to use the
optional quick-connection cables given below.
Main cable (3-core): CN-73-C1 (cable length 1m), CN-73-C2 (cable length 2m)
CN-73-C5 (cable length 5m)
Sub cable (1-core): CN-71-C1 (cable length 1m), CN-71-C2 (cable length 2m)
CN-71-C5 (cable length 5m)
2
MOUNTING
How to mount the amplifier
Fit the rear part of the mounting section of the amplifier
on a 35mm width DIN rail.
Press down the rear part of the mounting section of the
unit on the 35mm width DIN rail and fit the front part of
the mounting section to the DIN rail.
How to remove the amplifier
Push the amplifier forward.
Lift up the front part of the amplifier to remove it.
Note:
Take care that if the front part is lifted without pushing the amplifier forward, the hook on the
rear portion of the mounting section is likely to break.
How to connect the fiber cables
Be sure to fit the attachment to the fibers first before inserting the fibers to the
amplifier. For details, refer to the instruction manual enclosed with the fibers.
Snap the fiber lock lever down.
Insert the fiber cables slowly into the inlets until they
stop. (Note 1)
Return the fiber lock lever to the original position, till it
stops.
Notes: 1)
In case the fiber cables are not inserted to a position where
they stop, the sensing range reduces. In case of a flexible
fiber, take care that it may bend inside the amplifier, during
insertion.
2)
With the coaxial reflective type fiber, such as, FD-G4 or FD-FM2, insert the single-core fiber
cable into the beam-emitting inlet and the multi-core fiber cable into the beam-receiving
inlet. If they are inserted in reverse, the sensing accuracy will deteriorate.
INSTRUCTION MANUAL
ME-FX301HS No.0017-07V
PNP output
FX-301P-HS
12 to 24V DC 10% Ripple P-P 10% or less
(current consumption 40mA or less at 24V supply voltage)
(current consumption 25mA or less at 24V supply voltage)
<PNP output type>
PNP open-collector transistor
Maximum source current: 100mA (Note 1)
Applied voltage: 30V DC or less
(between output and +V)
Residual voltage: 1.5V or less
[at 100mA (Note 1) source current]
Incorporated
4 digit red LED display
Incorporated
(If 4 to 7 units are connected in cascade: -10 to +50 ,
35 to 85% RH, Storage: 35 to 85% RH
Red LED (modulated)
20g approx.
35mm width DIN rail
Fiber
lock lever
3
CONNECTION
Make sure that the power supply is off while connecting or disconnecting the quick-
connection cable.
Connection method
Holding the connector of the quick-connection cable, align
its projection with the groove at the top portion of the
amplifier connector.
Insert the connector till a click is felt.
Disconnection method
Pressing the projection at the top of the quick-connection
cable, pull out the connector.
Note:
Take care that if the connector is pulled out without pressing the
projection, the projection may break. Do not use a quick-
connection cable whose projection has broken. Further, do not pull
by holding the cable, as this can cause a cable-break.
4
CAUTIONS
This product has been developed / produced for industrial use only.
This product does not incorporate the optical communication function (copy
function and interference prevention function).
When the emission halt of the emitting power switching function is set from 'OFF' to
'ON', the output may be unstable. Do not use the output control for 0.5 sec. after
starting emission.
Make sure that the power supply is off while wiring.
Verify that the supply voltage variation is within the rating.
Take care that if a voltage exceeding the rated range is applied, or if an AC power
supply is directly connected, the sensor may get burnt or damaged.
In case noise generating equipment (switching regulator, inverter motor, etc.) is
used in the vicinity of this product, connect the frame ground (F.G.) terminal of the
equipment to an actual ground.
If power is supplied from a commercial switching regulator, ensure that the frame
ground (F.G.) terminal of the power supply is connected to an actual ground.
Do not use during the initial transient time (0.5 sec.) after the power supply is
switched on.
Take care that short-circuit of the load or wrong wiring may burn or damage the
sensor.
Do not run the wires together with high-voltage lines or power lines or put them in
the same raceway. This can cause malfunction due to induction.
Make sure to use the optional quick-connection cable for connection of the amplifier.
Extension up to total 100m (if 5 to 8 units are connected in cascade: 50m, if 9 to 16
units are connected in cascade: 20m) is possible with 0.3mm
However, in order to reduce noise, make the wiring as short as possible.
Take care that cable extension increases the residual voltage.
This sensor is suitable for indoor use only.
Avoid dust, dirt, and steam.
Take care that the product does not come in contact with water, oil, grease,
organic solvents, such as, thinner, etc., strong acid or alkaline.
This sensor cannot be used in an environment containing inflammable or explosive
gases.
Never disassemble or modify the sensor.
5
CASCADING
Make sure that the power supply is off while adding or removing the amplifiers.
Make sure to check the allowable ambient temperature, as it depends on the num-
ber of amplifiers connected in cascade.
In case two, or more, amplifiers are connected in cascade, make sure to mount
them on a DIN rail.
When the amplifiers move on the DIN rail depending on the attaching condition or
the amplifiers are mounted close to each other in cascade, fit them between the
optional end plates (MS-DIN-E) mounted at the two ends.
Up to maximum 15 amplifiers can be added (total 16 amplifiers connected in cascade.)
When connecting more than two amplifiers in cascade, use the sub cable (CN-71-C )
as the quick-connection cable for the second amplifier onwards.
When this sensor is used by cascading along with the other digital fiber amplifier,
since the optical communication function (copy function and interference preven-
tion function) is not incorporated, mount identical models together.
For mounting and removing the amplifier, refer to '
Cascading method
Mount the amplifiers, one by one,
on the 35mm width DIN rail.
Slide the amplifiers next to each
other, and connect the quick-con-
nection cables.
Mount the optional end plates
(MS-DIN-E) at both the ends to hold
the amplifiers between their flat sides.
Tighten the screws to fix the end
plates.
Fiber
Dismantling
Loosen the screws of the end plates.
Remove the end plates.
Slide the amplifiers and remove
them one by one.
Groove
Projection
Quick-connection cable
Projection
2
, or more, cable.
2
MOUNTING'.
Sub cable (CN-71-C )
(optional)
Main cable (CN-73-C )
(optional)
End plates (MS-DIN-E)
(optional)
End plates (MS-DIN-E)
(optional)
Slide
Slide

Advertisement

loading

Summary of Contents for Panasonic FX-301-HS

  • Page 1 Note: Take care that if the connector is pulled out without pressing the For further details on the fiber sensor amplifier, please refer to 'Panasonic Electric projection, the projection may break. Do not use a quick- Works SUNX website (http://panasonic-electric-works.net/sunx)' or contact our office.
  • Page 2 PRO mode I/O CIRCUIT DIAGRAMS PRO1 Refer to ' NPN output type MODE PRO1 Response time change function ' Stability function ' mode setting'. Terminal No. Timer setting function ' Shift function ' Color code of quick-connection cable Hysteresis function ' Emitting power selection function ' (Brown) +V (Note 1) Turn...
  • Page 3 Full-auto teaching is used when it is desired to set the threshold value without For details of the settings and the setting procedure of the PRO mode, refer to 'Panasonic Elec- stopping the assembly line, with the object in the moving condition.
  • Page 4 Phone: +81-568-33-7861 FAX: +81-568-33-8591 Europe Headquarter: Panasonic Electric Works Europe AG Rudolf-Diesel-Ring 2, D-83607 Holzkirchen, Germany Phone: +49-8024-648-0 US Headquarter: Panasonic Electric Works Corporation of America 629 Central Avenue New Providence, New Jersey 07974 USA Phone: +1-908-464-3550 PRINTED IN JAPAN...