C O N T E N T S P A R T I Cisco Remote PHY Shelf 7200 Start Up Configuration Guide for Cisco Remote PHY Shelf 7200 Software C H A P T E R 1 Cisco Remote PHY System Overview...
Page 4
How to Configure DEPI/UEPI/L2TP integration with RPD Configuring depi-class/l2tp-class Pair Verifying depi-class/l2tp-class Pair Configuration Verifying the RPD Status Display DEPI Ralated Information Feature Information for DEPI/UEPI/L2TP integration with RPD Cisco Remote PHY Shelf 7200 Software Configuration Guide for Cisco Remote PHY Shelf 7200 Software 1.1...
Page 5
C H A P T E R 8 Cisco Remote PHY Shelf 7200 Backhaul Port Mapping and Link Redundancy Hardware Compatibility Matrix for Cisco Remote PHY Shelf 7200 Cisco Remote PHY Shelf 7200 Software Configuration Guide for Cisco Remote PHY Shelf 7200 Software 1.1...
Page 6
Configure Controller in Fiber Node Verify CM RPD Association Display GCP Ralated Information Display DEPI Ralated Information Troubleshooting Tips Configuration Examples Example: Controller Profile Configuration Cisco Remote PHY Shelf 7200 Software Configuration Guide for Cisco Remote PHY Shelf 7200 Software 1.1...
Page 7
C H A P T E R 1 2 Cisco Remote PHY Shelf 7200 Trunk VLAN Configuration Hardware Compatibility Matrix for Cisco Remote PHY Shelf 7200 Cisco Remote PHY Shelf 7200 Software Configuration Guide for Cisco Remote PHY Shelf 7200 Software 1.1...
Page 8
Clearing All Events on Cisco cBR Database Viewing the RPD Events Viewing RPD Events Using Log Configuration Examples Example: RPD Event Configuration Feature Information for RPHY Fault Management Cisco Remote PHY Shelf 7200 Software Configuration Guide for Cisco Remote PHY Shelf 7200 Software 1.1 viii...
Page 9
Prerequisites for RPD Operations How to Access and Debug RPD Debugging RPD Debugging Cisco Smart PHY 7200 Feature Information for RPD Operations and Debugging Cisco Remote PHY Shelf 7200 Software Configuration Guide for Cisco Remote PHY Shelf 7200 Software 1.1...
Traditionally, DOCSIS runs on linear fiber (or HFC) to provide service and is not naturally applicable for digital fiber. Cisco has bridged the gap by introducing a new access technology called the Remote PHY.
Cisco Remote PHY Shelf 7200 Start Up Configuration Guide for Cisco Remote PHY Shelf 7200 Software 1.1 Hardware Compatibility Matrix for Cisco Remote PHY Shelf 7200 Need for the Cisco Remote PHY Solution DOCSIS and EuroDOCSIS are standards that define two-way operation over a cable network. DOCSIS provides the necessary Quality of Service (QoS) tools for ensuring voice call connectivity during periods of network congestion that are anticipated in triple-play networks.
Cisco cBR Series 8x10G Remote PHY Digital Physical Interface Card Data Sheet. The DPIC is installed in the CMTS and connected to the Cisco GS7000 node via the EPON, GPON, or Metro Ethernet. It supports both downstream and upstream traffic. Both the downstream and upstream traffic share the same ports.
• MACSec and 1588 TC Cisco Remote PHY Shelf 7200 The Cisco Remote PHY Shelf 7200 is a 7 rack unit (RU) chassis. It supports 13 RPD modules and 6 RF PICs. Below are some of its features: • 13 slots high availability chassis •...
Cisco Remote PHY Shelf 7200 Start Up Configuration Guide for Cisco Remote PHY Shelf 7200 Software 1.1 RPD Line Card Figure 1: Cisco Remote PHY Shelf 7200 RPD Line Card The Cisco Remote PHY Shelf 7200 RPD Line Card has the following features: •...
Page 18
The PIC card uses solid-state switch to create a switching path between the dedicated protect RPD in slot 6 and the 12 other RPDs in the Cisco Remote PHY Shelf 7200 chassis. The features of the Cisco Remote PHY Shelf 7200 PIC are: •...
Bring up process is prerequisite to the operation of the remote PHY system, just like the cable modem bring up in a DOCSIS system. Cisco Remote PHY Shelf 7200 Software Configuration Guide for Cisco Remote PHY Shelf 7200 Software 1.1...
Cisco Remote PHY Shelf 7200 Start Up Configuration Guide for Cisco Remote PHY Shelf 7200 Software 1.1 How to Bring Up Cisco Remote PHY Shelf 7200 How to Bring Up Cisco Remote PHY Shelf 7200 This section describes how to bring up Cisco Remote PHY Shelf 7200.
Page 21
Cisco Remote PHY Shelf 7200 Start Up Configuration Guide for Cisco Remote PHY Shelf 7200 Software 1.1 Configuring DHCP Server using IPv4 3. Define suboption. Fill in the name, type and repeat of suboption 61 as shown in the following figure.
Cisco Remote PHY Shelf 7200 Start Up Configuration Guide for Cisco Remote PHY Shelf 7200 Software 1.1 Configuring DHCP Server using IPv6 Stateless Configuring DHCP Server using IPv6 Stateless The Cisco Remote PHY System supports the Stateless Address Auto Configuration (SLAAC). IPv6 address assignment of the RPD is governed by the configuration bits set in the ICMPv6 Router Advertisement (RA) message and the presence of a valid prefix in the Prefix Information Option (PIO).
Cisco Remote PHY Shelf 7200 Start Up Configuration Guide for Cisco Remote PHY Shelf 7200 Software 1.1 Configuring PTP To display the RPD get IPv6 address by Stateful method, use the show dhcp command. R-PHY#show dhcp Interface IP-Address Subnet-Mask vbh0...
C H A P T E R Synchronizing Time on Cisco Remote PHY Shelf 7200 This section explains how to synchronize time on the RPD and CCAP core of the Cisco cBR Router. • Hardware Compatibility Matrix for Cisco Remote PHY Shelf 7200, on page 15 •...
Cisco Remote PHY Shelf 7200 Start Up Configuration Guide for Cisco Remote PHY Shelf 7200 Software 1.1 Remote DTI Time Protocol (PTP), helps in synchronizing time between a CCAP core function and a series of remote PHY devices (RPD) that enable R-PHY and provides support for converged DOCSIS, video, and out-of-band (OOB) services.
Page 29
Cisco Remote PHY Shelf 7200 Start Up Configuration Guide for Cisco Remote PHY Shelf 7200 Software 1.1 Configuring Time Interface and PTP domain Table 4: Parameters for time interface and PTP domain configuration Parameter Description Value Range Default Value ptp r-dti [id]...
Cisco Remote PHY Shelf 7200 Start Up Configuration Guide for Cisco Remote PHY Shelf 7200 Software 1.1 Verifying Time Interface and PTP Domain Configuration Parameter Description Value Range Default Value announce timeout [value] Set timeout interval for 3-255 announcement packets...
Cisco Remote PHY Shelf 7200 Start Up Configuration Guide for Cisco Remote PHY Shelf 7200 Software 1.1 Configuration Examples SIGNALING MANAGEMENT TOTAL 2607 2607 Configuration Examples This section provides examples for configuring Cisco cBR for time synchronization. Example: Configuring Time Interface and PTP Domain...
Cisco Remote PHY Shelf 7200 Start Up Configuration Guide for Cisco Remote PHY Shelf 7200 Software 1.1 Example: Associate R-DTI with RPD unicast grant-duration 300 local-priority 128 Example: Associate R-DTI with RPD The following example shows how to associate R-DTI with RPD:...
Cisco Remote PHY Shelf 7200 Start Up Configuration Guide for Cisco Remote PHY Shelf 7200 Software 1.1 Information about DEPI/UEPI/L2TP integration with RPD Information about DEPI/UEPI/L2TP integration with RPD DEPI Downstream External PHY Interface (DEPI) is the downstream interface between the CCAP Core and the RPD.
Cisco Remote PHY Shelf 7200 Start Up Configuration Guide for Cisco Remote PHY Shelf 7200 Software 1.1 Verifying the RPD Status rpd-us 0 upstream-cable 1/0/63 profile 100 depi depi_demo r-dti 1 rpd-event profile 0 When the RPD core is online, use the show l2tp tunnel command as shown in the example below:...
Cisco Remote PHY Shelf 7200 Start Up Configuration Guide for Cisco Remote PHY Shelf 7200 Software 1.1 Information about DEPI Latency Measurement Information about DEPI Latency Measurement The DEPI Latency Measurement (DLM) packet is a specific type of data packet used for measuring the network latency between the CCAP core and the RPD.
Cisco Remote PHY Shelf 7200 Start Up Configuration Guide for Cisco Remote PHY Shelf 7200 Software 1.1 Example: DLM Configuration Table 10: show cable rpd dlm Field Descriptions Field Description Last Average DLM It means the last time average DLM (AD). At first, the Last Average DLM (LAD) is...
Page 46
Cisco Remote PHY Shelf 7200 Start Up Configuration Guide for Cisco Remote PHY Shelf 7200 Software 1.1 Feature Information for DLM Cisco Remote PHY Shelf 7200 Software Configuration Guide for Cisco Remote PHY Shelf 7200 Software 1.1...
Cisco Remote PHY Shelf 7200 Start Up Configuration Guide for Cisco Remote PHY Shelf 7200 Software 1.1 Information about Multiple Cores Information about Multiple Cores The RPD can be managed by more than one CCAP core. An RPD is controlled by exactly one principal CCAP core and zero or more auxiliary CCAP core(s).
Cisco Remote PHY Shelf 7200 Start Up Configuration Guide for Cisco Remote PHY Shelf 7200 Software 1.1 Information About GCPP Support Information About GCPP Support The Generic Control Protocol (GCP) sets up a control plane tunnel over a generic transport protocol such as TCP or UDP.
Or add the DHCP pool with the GCPP core/CCAP core in the USD. Configuring Cisco cBR for Enabling GCPP To set the GCPP server as the core server, configure Cisco cBR to remove the principal keyword under RPD configuration. cable rpd <RPD name>...
P A R T Cisco Remote PHY Shelf 7200 High Availability Guide for Cisco Remote PHY Shelf 7200 Software • Cisco Remote PHY Shelf 7200 Backhaul Port Mapping and Link Redundancy, on page 45...
The HA RPHY Shelf has eight SFP+ ports. These ports can be configured in 4+4 or 6+2 modes. By default, redundancy is not configured. Cisco Remote PHY Shelf 7200 Software Configuration Guide for Cisco Remote PHY Shelf 7200 Software 1.1...
Page 58
Cisco Remote PHY Shelf 7200 High Availability Guide for Cisco Remote PHY Shelf 7200 Software 1.1 Port Mapping and Redundancy In the 4+4 mode, four 10GE ports are available in a redundant configuration, where four 10GE ports are active and the corresponding four 10GE ports are redundant. For example, backhaul port 4 protects backhaul port 0 while backhaul port 5 protects backhaul port 1.
Page 59
Cisco Remote PHY Shelf 7200 High Availability Guide for Cisco Remote PHY Shelf 7200 Software 1.1 Port Mapping and Redundancy Figure 4: Default 6+2 Port Mapping In this mode, if all SFP+ ports are active and the default port mapping is configured, then each PHY device can receive up to 10Gbps unicast traffic or 6Gbps unicast and 4Gbps multicast traffic from the backhaul network.
Cisco Remote PHY Shelf 7200 High Availability Guide for Cisco Remote PHY Shelf 7200 Software 1.1 Restrictions for Port Mapping Figure 5: Example of Port Mapping with One SFP+ Port To switch between 4+4 mode and 6+2 mode, you can use backhaul mode switch or change using the command line interface.
Cisco Remote PHY Shelf 7200 High Availability Guide for Cisco Remote PHY Shelf 7200 Software 1.1 Configure Port Mapping and Link Redundancy Configure Port Mapping and Link Redundancy This section describes how to configure port mapping and link redundancy on the Cisco Remote PHY Shelf 7200.
Cisco Remote PHY Shelf 7200 High Availability Guide for Cisco Remote PHY Shelf 7200 Software 1.1 Verify Link Redundancy show bh-erpd-mapping slot number This is an example of verifying port mapping. Router# show bh-erpd-mapping slot 0 LC 0 : backhaul0 <---> erpd0 backhaul0 <--->...
Cisco Remote PHY Shelf 7200 High Availability Guide for Cisco Remote PHY Shelf 7200 Software 1.1 Feature Information for Port Mapping and Link Redundancy --------------------------- Backhaul |State Role ---------|----------------- |Active Primary |Standby Secondary ---------|----------------- |Active Primary |Standby Secondary ---------|----------------- |Active...
Page 64
Cisco Remote PHY Shelf 7200 High Availability Guide for Cisco Remote PHY Shelf 7200 Software 1.1 Feature Information for Port Mapping and Link Redundancy Cisco Remote PHY Shelf 7200 Software Configuration Guide for Cisco Remote PHY Shelf 7200 Software 1.1...
P A R T Cisco Remote PHY Shelf 7200 Configuration Guide for Cisco Remote PHY Shelf 7200 Software • Cisco Remote PHY Controller Profile and RPD Configuration, on page 55 • Dynamic Bonding Group for RPHY, on page 69 •...
C H A P T E R Cisco Remote PHY Controller Profile and RPD Configuration This document describes how to configure the Cisco Remote PHY Controller Profile and RPD on the Cisco cBR Series Converged Broadband Router. Finding Feature Information Your software release may not support all the features that are documented in this module.
Downstream 1:1 mapping is not supported under 512 RPD configuration, but still supported under smaller scale configuration. Prerequisites for Configuring Controller Profile and RPD The following restrictions are applicable to configuring controller profiles: Cisco Remote PHY Shelf 7200 Software Configuration Guide for Cisco Remote PHY Shelf 7200 Software 1.1...
Verify CM RPD Association To verify the RPD associated with the cable modem, use the show cable modem rpd command as shown in the following example: Cisco Remote PHY Shelf 7200 Software Configuration Guide for Cisco Remote PHY Shelf 7200 Software 1.1...
Use Cisco Feature Navigator to find information about the platform support and software image support. Cisco Feature Navigator enables you to determine which software images support a specific software release, Cisco Remote PHY Shelf 7200 Software Configuration Guide for Cisco Remote PHY Shelf 7200 Software 1.1...
Page 79
Cisco Remote PHY Shelf 7200. US 128 channels Cisco Remote PHY Shelf 7200 This feature was introduced on the Software 1.1 Cisco Remote PHY Shelf 7200. Cisco Remote PHY Shelf 7200 Software Configuration Guide for Cisco Remote PHY Shelf 7200 Software 1.1...
Page 80
Cisco Remote PHY Shelf 7200 Configuration Guide for Cisco Remote PHY Shelf 7200 Software 1.1 Feature Information for Controller Profile and RPD Configuration Cisco Remote PHY Shelf 7200 Software Configuration Guide for Cisco Remote PHY Shelf 7200 Software 1.1...
To configure the bonding group reclaim threshold, use cable dynamic-bonding-group reclaim-threshold command as shown in the following example: ROUTER# configure terminal ROUTER(config)# cable dynamic-bonding-group reclaim-threshold percent 5% modems 6 ROUTER(config)# end Cisco Remote PHY Shelf 7200 Software Configuration Guide for Cisco Remote PHY Shelf 7200 Software 1.1...
Wi3/0/1:3 Check the modem’s downstream tuner capability using the show cable modem verbose | in DS Tuner command as shown in the following example: Cisco Remote PHY Shelf 7200 Software Configuration Guide for Cisco Remote PHY Shelf 7200 Software 1.1...
Page 84
The modem is moved out of the bonding group. RECLAIM_WAITING_SUP Line card sends a DBG reclaim request and waits for SUP to reclaim the BG. Cisco Remote PHY Shelf 7200 Software Configuration Guide for Cisco Remote PHY Shelf 7200 Software 1.1...
The difference between the total number of WBCMs used with any two channels is smaller or equal to the minimum threshold load. The default value of the minimum threshold load is 5. Cisco Remote PHY Shelf 7200 Software Configuration Guide for Cisco Remote PHY Shelf 7200 Software 1.1...
To check the potential target bonding group for each of the source bonding group, use the show cable load-balance docsis-group target dbg and the show cable load-balance docsis-group target wide commands as shown in this example: Cisco Remote PHY Shelf 7200 Software Configuration Guide for Cisco Remote PHY Shelf 7200 Software 1.1...
• For RPHY Shelf 7200, user can use ethernet 1 for all 6 eRPDs in a RPD linecard, or use ethernet 1 to 6 for these eRPDs. 3. Associate R-DTI with RPD configuration. configure terminal cable rpd r-dti number Cisco Remote PHY Shelf 7200 Software Configuration Guide for Cisco Remote PHY Shelf 7200 Software 1.1...
C H A P T E R Cisco Remote PHY Shelf 7200 Trunk VLAN Configuration This document describes how to configure trunk VLAN for the Cisco Remote PHY Shelf 7200 Software 1.1. • Hardware Compatibility Matrix for Cisco Remote PHY Shelf 7200, on page 87 •...
Cisco Remote PHY Shelf 7200 Management Guide for Cisco Remote PHY Shelf 7200 Software 1.x Configure Trunk VLAN Each Remote PHY Shelf 7200 device has six uplink ports. Each upink port has two VLAN modes—access mode and trunk mode. Access mode is the default mode.
C H A P T E R Cisco Remote PHY Shelf 7200 Software Image Upgrade This document describes how to upgrade the software image for the Cisco Remote PHY Shelf 7200 Software 1.1. • Hardware Compatibility Matrix for Cisco Remote PHY Shelf 7200, on page 91 •...
Verifying Software Upgrade Verifying Software Upgrade From the Cisco cBR-8 Router To view the status of the software upgrade from the Cisco cBR-8 router, use the show cable rpd-upgrade group [all| group id] status command. Router# show cable rpd-upgrade group all status GROUP-ID: 7abd.44a1.0000...
Abort Software Upgrade Abort Software Upgrade From the Cisco cBR-8 Router To abort software upgrage from the Cisco cBR-8 router, use the cable rpd group all upgrade abort command. Router# cable rpd group all upgrade abort Abort software upgrade process successfully.
C H A P T E R Cisco Remote PHY Shelf 7200 Fault Management This document describes how to configure the events for fault management on the Cisco Remote PHY Shelf 7200 Software 1.1. • Hardware Compatibility Matrix for Cisco Remote PHY Shelf 7200, on page 95 •...
• During run-time operations, RPD notifies the CCAP Core of the events Restrictions for Configuring RPD Events Following restrictions are applicable: A maximum of 1000 events are retained on Cisco cBR. The RPD retains 1000 events locally and 1000 events in pending state. How to Configure RPD Events...
• ip_address—IP address of the server • port_number—UDP port number assigned to receive the SNMP traps. The same port number must also be configured on the SNMP server. Cisco Remote PHY Shelf 7200 Software Configuration Guide for Cisco Remote PHY Shelf 7200 Software 1.1...
Router#cable rpd 30.84.2.111 event pending Clearing All Events on Cisco cBR Database To remove all Events on Cisco cBR, use the clear cable rpd all event command, as given in the following example: Router# clear cable rpd event group RPD_MAC...
C H A P T E R Cisco Remote PHY Shelf 7200 Device Operations and Debugging This document describes the operations and debugging of the Cisco Remote PHY Shelf 7200 Software 1.1. • Hardware Compatibility Matrix for Cisco Remote PHY Shelf 7200, on page 101 •...
EXEC mode. • To display eRPD related information, use the show erpd command in privileged EXEC mode. • To view virtual LAN configuration on your Remote PHY Shelf 7200 device, use the show trunk vlan command in privileged EXEC mode.