Power Supply; Water Connection - AEG OKO-LAVAMAT 86820 User Instructions

Table of Contents

Advertisement

Installation and Connection Instructions

Power supply

Information concerning line
voltage, current type and
required fusing can be found
on the type plate. The type
plate is located at the top
behind the fill-in door.
For permanent electrical con-
nection within the electrical
circuit, provisions must be made which allow for electrical disconnec-
tion of the appliance from the mains with a contact opening of at least
3 mm at all poles. Suitable devices include circuit breakers, fuses
(threaded fuses must be entirely removed from the socket), ground
fault circuit interrupters and contactors. Permanent connection may
only be carried out by an authorised electrician.
This appliance conforms to the following EC directives
;
– "Low-Voltage Guideline" 73/23/EWG dated 19 February 1973
and guideline amendment 93/68/EWG
– "EMC Guideline" 89/336/EWG dated 3 May 1989
and guideline amendment 93/68/EWG

Water connection

The washing machine is provided with safety devices which prevent
3
reverse pollution of drinking water and conform to the State regulati-
ons issued by water supply authorities (e.g. in Germany: DVGW Directi-
ves). Further protective measures in the installation are hence
unnecessary.
Attention! Appliances for cold water connection may not be connec-
ted to warm water!