through the passage. Minimum passage
between the boundary wire is 60 cm / 24 in.
If the work area has areas which are
connected by a narrow passage (B), you
can set the product to leave the guide wire
after a certain distance (C). The settings can
Remote start 1 on page 21 .
be changed in
If the work area includes a secondary area
(D), refer to
To make a secondary area on
page 17 . Put the product in the secondary
Proportion .
area and select

3.4 Installation of the product

3.4.1 To install the charging station
WARNING: Obey national regulations
about electrical safety.
1.
Read and understand the instructions about
the charging station. Refer to
where to put the charging station on page
14 .
2.
Put the charging station in the selected area.
3.
Connect the low-voltage cable to the
charging station.
4.
Put the power supply at a minimum height of
30 cm / 12 in.
min 30 cm / 12"
CAUTION: The product is only to
be used with the power supply
unit supplied by Husqvarna
WARNING: Do not put the power
supply at a height where there is a
risk it can be put in water. Do not
put the power supply on the
ground.
WARNING: Do not encapsulate
the power supply. Condensed
18 - Installation
5.
Connect the power supply cable to a
100-240V outdoor power outlet.
6.
Put the low-voltage cable in the ground with
stakes or bury the cable. Refer to
wire into position with stakes on page 19 or
To bury the boundary wire or the guide wire
on page 19 .
To examine
7.
Connect the wires to the charging station.
Refer to
page 18 and To install the guide wire on
page 19 .
8.
Attach the charging station to the ground
with the supplied screws.
3.4.2 To install the boundary wire
1.
Put the boundary wire around all of the work
area. Start and complete the installation
behind the charging station.
®
.
2.
Open the connector and put the boundary
wire in the connector.
water can harm the power supply
and increase the risk of electrical
shock.
WARNING: Applicable to USA/
Canada. If power supply is
installed outdoors: Risk of Electric
Shock. Install only to a covered
Class A GFCI receptacle (RCD)
that has an enclosure that is
weatherproof with the attachment
plug cap inserted or removed.
To put the
To install the boundary wire on
CAUTION: Do not make new
holes in the charging station plate.
CAUTION: Do not put your feet on
the charging station.
CAUTION: Do not put unwanted
wire in a coil. The coil causes
interference with the product.