1-1. Overview

Intelligent Device Controller (iDC) boards BKSI-2040 series (BKSI-2042/2043/2044) and BKSI-2440
series (BKSI-2440/2441) are installed in System Interface Unit SIU-80A/80, so as to control the devices
(Network Storage System, VTR, Routing Switcher, etc.) which are used in Server Management System
(SMS).
. The required power for operation of each board is supplied from System Interface Unit SIU-80A/80.
. The model label (1 set) is supplied with each board.
BKSI-2440 : iDC CPU BOARD (CPU-356 BOARD)
This is the main CPU board, and is used for the following two purposes.
1. For root controller
Transmits the application commands sent through the SMS gateway to the iDC boards
controlled each device.
Multiple iDC boards controlling each device can be controlled by only one this board that is installed
in each Server Management System (SMS).
(The number of iDC boards which can be controlled by one this board depends on the installing
application software.)
*: Hereinafter, BKSI-2440/2441/2042/2043/2044 is described as iDC board.
2. For device controller
Each device of the SMS can be controlled when this board is used as a pair with each board BKSI-
2042, BKSI-2043 or BKSI-2044.
BKSI-2441 : iDC LINK INTERFACE BOARD (IF-905 BOARD)
This connector panel carrys out the interface with SMS gateway, or the interface between iDC boards.
BKSI-2042 : IDC SERIAL I/F CONNECTOR BOARD (IO-111 BOARD)
This connector panel is used for the RS-232C/422A interface.
Use this panel a pair with device controller BKSI-2440.
For details, refer to the Installation Manual for BKSI-2040.
BKSI-2043 : IDC PARALLEL I/F CONNECTOR BOARD (IO-109 BOARD)
This connector panel is used for the interface of the input and output signals at
the parallel contacts.
Use this panel a pair with device controller BKSI-2440.
For details, refer to the Installation Manual for BKSI-2040.
BKSI-2044 : IDC S-BUS I/F CONNECTOR BOARD (IO-110 BOARD)
This connector panel is used for the S-BUS/VS-BUS interface.
Use this panel a pair with device controller BKSI-2440.
For details, refer to the Installation Manual for BKSI-2040.
n
To control the devices with the boards described above, the optional software (Server Management
Software BSS-1) is required.
Refer to the Installation manual supplied with the software for the installation procedures.