Download Print this page

Installation; Rear Panel; Front Panel - Bosch LTC 8782 Series Instructions For Use Manual

Control code translators allegiant biphase to vicon rs-422
Hide thumbs Also See for LTC 8782 Series:

Advertisement

Bosch
biphase
input.
Power
Indicator
Because of the different nature of Bosch and Vicon code structure, the indicators will show differ-
ent patterns. The Rx indicator will flicker while Bosch biphase code is being received. (If the
polarity is reversed, it should not light.) The Tx indicator will flash only when the Vicon output
command changes. Thus if you initiate a Bosch pan command, the Rx inidicator should flicker as
long as the joystick is deflected, but the Tx indicator will flash only at the start of the pan and again
at the end, or whenever the speed is changed.
The Rx indicator will also indicate if Bosch is sending data other than camera control commands.

INSTALLATION

REAR PANEL

Vicon RS-422 Outputs
Connect to CMD IN + & -.
The code translator operates
in simplex mode, the RSP
lines are not used.

FRONT PANEL

Rx Indicator
(Flashes when
receiving biphase
code)
4
Power
Input
Tx Indicator
(Flashes when
sending
Vicon code)