Ambient Conditions - Bosch Rexroth LU 2 Assembly Instructions Manual

Automatic lubrication unit
Table of Contents

Advertisement

17.2 Ambient conditions

• The transfer systems are designed for stationary use in weather-protected areas.
• Working temperature:
+5 °C to +40 °C
–5 °C to +60 °C at 20% reduced load
• Storage temperature
–25 °C to +70 °C
• Relative humidity
5% to 85%, non-condensing
• Air pressure
> 84 kPa corresponds to an altitude < 1400 m above sea level
• Permissible load capacity of fl oor: 1000 kg/m
• At altitudes > 1400 m, the load values of the electric drives are reduced by 15%.
• Prevent mold, fungus, rodents, and other vermin.
• Installation and operation in the immediate vicinity of industrial equipment
with chemical emissions is not permitted.
• Do not install or operate near sources of sand or dust.
• Do not install and operate in areas which are regularly jarred by high forces caused
by, for example, presses or heavy machinery.
• Resistant to many common media used in production such as water, mineral
oil, grease, and detergents. If you are unsure about resistance against certain
chemicals such as test oil, doped oils, aggressive detergents, solvents, or brake
fl uid, we recommend that you consult with your specialized Rexroth representative.
• Avoid long-term contact with acidic or basic reacting materials.
Technical data
2
3 842 358 814/2017-01, MIT: LU 2, Bosch Rexroth AG
53/54

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents