Gaming access to the parts
33
Side panels
After the rear panel has been detached, the side panels may be removed
by sliding them slightly backwards and subsequently lifting them sideways
out of the frame.
Bottom panel
After detaching the rear panel, the bottom panel may be removed by
unscrewing the four screws "C" (Fig. 16).
B. REMOVING THE KNOBS (Fig. 15)
Single knobs
- Remove cap "A".
- Loosen nut "B". The knob may now be slid off the spindle.
Double knobs
- Remove cap "A".
- Loosen nut "B". Now the smallest knob can be slid off the spindle.
- Loosen nut "C". Now the large knob can be slid off the spindle.
-010
C
B
Fig. 15. Removing the knobs
C, REMOVING THE FRONT PANEL
- Remove the cabinet panels according to section II.A.
- Remove the knobs according to section II.B.
- Unsolder the connecting wires of sockets BUI and BU6.
- Unscrew the rings of sockets BU2 . . . BU5.
- Remove the 10 screws "S" (Fig. 16).
- Remove the front panel (consisting of front frame and text plate).