GE
Lighting Solutions
Tetra
LED Systems Power Supply
®
(GEPS24-100U-GL)
Power Supply Features
• Supports Tetra PowerStrip DS, Tetra miniStrip DS, Tetra EdgeStrip,
Tetra Contour and Tetra Contour LS LED lighting systems
• UL: Class 2 wiring per NEC Article 725, dry and damp location rated
• IEC: SELV, CE: IP66 rated, separate enclosure required
BEFORE YOU BEGIN
Read these instructions completely and carefully.
RISK OF ELECTRIC SHOCK:
• Disconnect power at fuse box or circuit breaker before servicing or
installing product.
• Properly ground Tetra
power supply.
®
RISK OF FIRE:
• Use only Tetra
supply wire to make connection from Tetra
®
supply to Tetra
LED strip.
®
• Use only approved wire for input/output connection.
Minimum size 18 AWG (0.82 mm
• Follow all local codes.
Power Supply Installation
Brown (line)
AC line
1
Connect the AC line to the brown
(line) and blue (neutral) input
wires of the power supply using
18-14 AWG (0.82-2.08 mm
18-10 AWG (0.82-5.26 mm
wire connectors.
imagination at work
WARNING/AVERTISSEMENT
)
2
Input
wires
Red (+)
Blue (neutral)
2
Connect the supply wire that is
attached to the Tetra LED System to
the red (+) and black (-) output wires
) or
of the power supply as outlined
2
) twist-on
in the "Electrical Connections"
2
section of your LED system's
Installation Instructions.
RISQUES DE DÉCHARGES ÉLECTRIQUES
• Coupez l'alimentation électrique à la boîte de fusibles ou au
disjoncteur avant l'entretien ou l'installation du produit.
• Assurez-vous de correctement mettre à terre l'alimentation
électrique Tetra
RISQUES D'INCENDIE
power
®
• N'utilisez que le fil d'approvisionnement Tetra
connexion entre l'alimentation Tetra
• N'utilisez que des fils approuvés pour les entrées/sorties de
connexion. Taille minimum 18 AWG (0.82 mm
• Respectez tous les codes locaux.
To Tetra LED System
Black (-)
Output
wires
Installation Guide
.
®
®
et la bande DEL Tetra
®
).
2
24
Volt
pour faire la
.
®