Interrupts, error messages and diagnostics and system alarms
9.3 Diagnostics
Parameters of the Diagnostics Tool
The following table provides an overview of the supported command line commands:
Parameter
-k
-i
-v
-m
-h
Result
The Diagnostics Tool checks the parameters for the selected path.
Figure 9-1
SMBIOS (System Management BIOS) test
The Diagnostics Tool checks whether the SMBIOS values are readable and the data
structure is consistent.
90
--kernel-path
--ipaddr-vnic
--verbose
--mount-path
--Help
Output result of the Diagnostics Tool
Explanation
Active path of the kernel version.
If the kernel is updated after the installation, use this parameter to
identify the new kernel path. Otherwise, the tool automatically finds
the active kernel path.
Enter the IP address of the runtime communication interface of the
CPU. If you do not specify this parameter, the tool uses the default IP
address: 192.168.73.1.
To collect detailed data for failed test cases, enable verbose mode.
Inserts the path for "/dev/sda3".
Displays the infotext in the command line editor.
CPU 1505SP (F) Ready4Linux Version 2.7
Operating Instructions, 05/2019, A5E46864285-AA