2. INTRODUCTION & SpECIFICATIONS
A range of pond pumps suitable for creating garden water features such as fountains and waterfalls. They also provide the important
functions of filtration and water circulation which are necessary to maintain healthy plant and fish life. Each pump is supplied with 5
fountain heads (fig.3) and 10m of cable.
Technical Data.
Model:
Power Consumption:
Max. Head:
Max. flow Rate:
Max. Submersion Depth:
Power Cable:
Max. Temp. of the Pumped fluid:
Input:
Protection Type:
3. OpERATING INSTRUCTIONS
WARNING! Ensure that you read, understand and apply the safety instructions in Section 1.
3.1.
Start-up.
3.1.1. Place the pump on a flat level surface which is raised from the bottom of the pond. This prevents the pump from clogging too quickly.
3.1.2. You may use the pump lying on its side. You should however, make sure that the motor axis is horizontal, otherwise the shaft will be subject
to increased wear.
3.2.
Cascade Fountain Mode.
3.2.1. When installing the pump in the pond, make sure that the fountain head projects above the water surface. Please refer to
fig 1 and ensure the regulating valve fig 1.1 is set at o° (turned all the way to the right). The delivery heights and diameters in fig 1
correspond to a condition in which the fountain head is placed 50mm above the water surface.
Fig 1
Refer to Fig 1.
Diameter of 1st stage "C"
Diameter of 2nd stage "B"
Delivery head of 1st stage "D"
Delivery of second stage "E"
Max. delivery head "f"
Refer to Fig 1
Distance from pump outlet to fountain head "G" 240-395mm
Distance from pump base to fountain head "H" 365-520mm
3.3
Fountain Heads.
3.3.1. A selection of fountain heads are supplied with the pump (fig 3). Choose the desired style and install onto the outlet pipe.
3.4.
Fountain and Water Spout Connection.
3.4.1. Additional water spectacles can be connected to the water spout connection (fig.1.2) with a hose of 19mm OD .
3.4.2. To open the spout connection, turn the regulating valve (fig 1.1) anticlockwise between 0-90° to adjust the flow between
the spout and the fountain head.
3.5.
Water Spout Only.
3.5.1. Turn the regulating valve all the way anticlockwise to 90°. All the water flow will now be through the water spout.
Wpp2300
Wpp2650
55W
2.3mtr
2300ltr/h
2.3mtr
10mtr
35°C
230V
IP68
1
Wpp2300
Wpp2650
1100mm
1200mm
800mm
1000mm
700mm
1100mm
1450mm
1300mm
1800mm
Wpp2300
255-410mm 255-410mm
380-535mm 380-535mm
Original Language Version
Wpp3500
75W
2.7mtr
2650ltr/h
3500ltr/h
2.7mtr
10mtr
35°C
230V
IP68
2
Wpp3500
1320mm
1100mm
900mm
990mm
1595mm
1980mm
Wpp2650
Wpp3500
95W
3.0mtr
3.0mtr
10mtr
35°C
230V
IP68
Fig 2
WPP2300, WP2650, WPP3500