Download Print this page

Sealey POWER PRODUCTS SM22/C Instructions page 2

Workshop air powered cleaning tank

Advertisement

4. AIR SUPPLY
4.1.
Ensure that the tank air valve is closed before connecting the air supply.
4.2.
An air pressure of 65-125psi and an available air volume of 8-10cfm will be required to operate the unit.
WARNING! Ensure air supply is clean and does not exceed 125psi. Too high an air pressure and/or unclean air will shorten
the product life due to excessive wear and may be dangerous, causing possible damage and/or personal injury.
Air supply must be equipped with regulator, water trap and oiler.
4.3.
Drain the air supply tank daily. Water in the air line will damage the unit.
4.4.
Clean the air supply filter weekly. For recommended hook-up, see diagram.
4.5.
Line pressure should be increased to compensate for unusually long air
hoses (over 8 metres). The minimum hose internal diameter should be
10mm and fittings must have the same internal dimension.
4.6.
Keep hose away from heat, oil and sharp edges. Check hoses for
wear, and make certain that all connections are secure.
4.7.
The air inlet connection is
5. OPERATING INSTRUCTIONS
WARNING! Read and apply Section 1 safety instructions before using the
cleaning tank.
IMPORTANT! You must remove the transit bolt from the
in fig.1 as the fire safety mechanism will not work if the bolt remains in place.
5.1.
Check the air regulator valve (fig.2.1) is off, and air inlet (2) is disconnected from the
air supply.
5.2.
Fill the tank to appropriate capacity (See specifications) with Sealey solvent, or a
general purpose degreaser (contact your local dealer for supply). DO NOT use any
other type of solvent.
CAUTION! Ensure you follow any instructions provided with the solvent.
5.3.
Connect washer to the air supply, aim flexible nozzle (3) into tank and turn valve (1)
on. Check that solvent flows freely through the flexible nozzle.
5.4.
Place parts to be cleaned into the cleaning basket. Direct spray nozzle onto parts. Ensure any splash back stays inside the tank, if not
reposition the spray nozzle. Adjust the air flow valve (1) to give the minimum output for the task.
5.5.
The supplied brush may be attached to the nozzle to assisted cleaning if required.
5.6.
For stubborn and ground in marks, leave the parts to soak in the bottom of the tank. Place the turbo nozzle (7) in the solvent and turn
the turbo mode valve (5) on. This will agitate the solvent and assist cleaning.
5.7.
When parts are clean, turn off the pump and leave the parts to drain in the basket or on the shelf.
5.8.
To assist drying the air blow gun (4) may be used.
5.9.
When complete, turn the washer off and disconnect from the air supply.
5.10.
SOLVENT REPLACEMENT
WARNING! It is operator's responsibility to ensure that there is no uncontrolled discharge of
any fluids used with this unit and that appropriate arrangements have been made for correct
disposal of waste in accordance with government/local authority regulations.
WARNING! Disconnect the air supply from the unit before changing accessories, servicing or
performing any maintenance.
WARNING! Wear approved safety gloves, goggles, mask and suitable clothing.
5.10.1. To empty used solvent, loosen sediment in the bottom of the tank by use of the turbo mode, then
open base plug to drain.
Completely drain dirty solvent into appropriate receptacle. Clean inside of tank and strainer before
refilling with clean solvent.
5.10.2. Store the used solvent in accordance with regulations.
5.10.3. Wipe up any spillage immediately. When cleaning parts ensure that nothing in the tank,
including any parts basket, is in a position that would prevent the lid from closing fully if and
when the fusible link activates.
6. MAINTENANCE
WARNING! Disconnect the air supply from the unit before changing accessories, servicing or performing any maintenance.
6.1.
Keep the cleaning tank clean. Remove and clean the filter (fig 1.6) regularly for best and safest performance.
6.2.
Regularly check and top up the oil in the air supply oiler.
6.3.
Keep the outside of the unit clean.
6.4.
DO NOT modify or jam the parts washer lid open, as this will make the fusible fire link inoperative which is dangerous practice and will
invalidate the warranty and your insurance.
NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
IMPORTANT: No liability is accepted for incorrect use of this product.
WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.
INFORMATION: For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.
1/4"BSP.
Sole UK Distributor, Sealey Group,
Kempson Way, Suffolk Business Park,
Bury St. Edmunds, Suffolk,
IP32 7AR
Original Language Version
lid stay as indicated
01284 757500
01284 703534
HOOK-UP
Fig.1
fig.2
www.sealey.co.uk
Web
sales@sealey.co.uk
email
SM22/C
Issue: 2 - 17/03/10

Advertisement

loading