Download Print this page
Sealey GDM200F/VS Instructions

Sealey GDM200F/VS Instructions

Variable speed pillar drill

Advertisement

Quick Links

thank you for purchasing a sealey product. Manufactured to a hIgh standard this product will, if used according to these instructions and
properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS AND CAUTIONS.
USE THIS PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE
DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.
1. SAFETY INSTRUCTIONS
1.1.
ELECTRICAL SAFETY
 WARNING! It is the responsibility of the owner and the operator to read, understand and comply with the following:
You must check all electrical products, before use, to ensure that they are safe. You must inspect power cables, plugs, sockets and any other
connectors for wear or damage. You must ensure that the risk of electric shock is minimised by the installation of appropriate safety devices. A
residual current circuit Breaker (rccB) should be incorporated in the main distribution board. We also recommend that a residual current
Device (rcD) is used. It is particularly important to use an rcD with portable products that are plugged into a supply which is not protected
by an rccB. If in any doubt consult a qualified electrician. You may obtain a residual current Device by contacting your sealey dealer.
You must also read and understand the following instructions concerning electrical safety.
1.1.1. the Electricity at Work Act 1989 requires all portable electrical appliances, if used on business premises, to be tested by a qualified
electrician, using a Portable Appliance tester (PAt), at least once a year.
1.1.2. the Health & Safety at Work Act 1974 makes owners of electrical appliances responsible for the safe condition of those appliances
and the safety of the appliance operators. If in any doubt about electrical safety, contact a qualified electrician.
1.1.3. Ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply. see 1.1.1. and 1.1.2.
and use a Portable Appliance tester.
1.1.4. Ensure that cables are always protected against short circuit and overload.
1.1.5. regularly inspect power supply cables and plugs for wear or damage and check all
connections to ensure that none is loose.
1.1.6. Important: Ensure that the voltage marked on the appliance matches the power supply
to be used and that the plug is fitted with the correct fuse - see fuse rating at right.
1.1.7. DO NOT pull or carry the appliance by the power cable.
1.1.8. DO NOT pull the plug from the socket by the cable.
1.1.9. DO NOT use worn or damaged cables, plugs or connectors. Immediately have any faulty
item repaired or replaced by a qualified electrician. When an AstA/Bs approved uK
3 pin plug is damaged, cut the cable just above the plug and dispose of the plug safely.
fit a new plug according to the following instructions (uK only).
a) Connect the GREEN/YELLOW earth wire to the earth terminal 'E'.
b) Connect the BROWN live wire to the live terminal 'L'.
c) Connect the BLUE neutral wire to the neutral terminal 'N'.
d) After wiring, check that there are no bare wires, that all wires have been correctly
connected, that the cable outer insulation extends beyond the cable restraint and that the restraint is tight.
Double insulated products, which are always marked with this symbol
to rewire, connect the wires as indicated above - DO NOT connect either wire to the earth terminal.
1.1.10. Products which require more than 13 amps are supplied without a plug. In this case you must contact a qualified electrician to ensure
that a suitably rated supply is available. We recommend that you discuss the installation of an industrial round pin plug and
socket with your electrician.
1.1.11. If an extension reel is used it should be fully unwound before connection. A reel with an rcD fitted is preferred since any appliance
plugged into it will be protected. the cable core section is important and should be at least 1.5mm², but to be absolutely sure that the
capacity of the reel is suitable for this product and for others which may be used in the other output sockets, we recommend the use of
2.5mm² section cable.
1.2. GENERAL SAFETY
WARNING! Disconnect drill from mains power before changing accessories, servicing or performing any
maintenance.
Maintain the drill in good condition (use an authorised service agent).
WARNING! Keep all guards and holding screws in place, tight and in good working order. Check regularly for
damaged parts. A guard, or any other part, that is damaged must be repaired or replaced before the tool
is next used, to ensure that it will operate properly and perform its intended function. The safety guard is a
mandatory fitting where the drill is used on premises covered by the Health & Safety at Work Act.
check alignment of moving parts and check for possible broken parts.
replace or repair damaged parts. use recommended parts only. unauthorised parts may be dangerous and will
invalidate the warranty.
Ensure that the head frame set screws are tight before using the drill.
secure the drill to a supporting structure to avoid the machine tipping, sliding or walking. Drill is designed for use
with drill bits and mortice attachments only. no other accessory may be used.
Ensure the chuck is securely fastened to the spindle.
remove chuck keys and wrenches from the machine and work area before switching on.
use clamps or a vice (not included but available from your sealey dealer). Do not secure the workpiece by hand.
refer to speed chart for recommended drilling speeds.
WARNING! Always wear approved eye or face protection when operating this drill. Use a face or dust
mask if dust is generated.
WARNING! DO NOT wear gloves when drilling.
InstructIons for:
VARIABLE SPEED PILLAR DRILL
MoDEL nos:
, are fitted with live (brown) and neutral (blue) wires only.
Original Language Version
GDM200F/VS
Yellow & Green
Earth Wire
Blue
Neutral
Wire
FUSE RATING 13 AMP
GDM200f-Vs
Brown
Live
Wire
Cable
Restraint
Issue no.1
27/02/12

Advertisement

loading

Summary of Contents for Sealey GDM200F/VS

  • Page 1 Device (rcD) is used. It is particularly important to use an rcD with portable products that are plugged into a supply which is not protected by an rccB. If in any doubt consult a qualified electrician. You may obtain a residual current Device by contacting your sealey dealer.
  • Page 2 “no-Volt release” switches which prevent accidental restart after a mains power interruption. A rack and pinion feed shaft with preset depth control for repetitive work is also included. Work clamps, vices and mortising attachments are available for these drills, contact your local sealey dealer for information. 3. TECHNICAL SPECIFICATIONS...
  • Page 3 Drill mounting 5.2.1. for stability and safety it is important that the drill base is securely bolted to the workbench (GDM150B/Vs) or floor (GDM200f/Vs). 5.2.2. Ensure that the mounting surface is capable of supporting the drill together with the weight of the heaviest likely workpiece.
  • Page 4 WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim. INFORMATION: for a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode. Sole UK Distributor, Sealey Group, www.sealey.co.uk...