Generator inverter 1500w 230v

Advertisement

4.3
AC APPLICATIONS
WARNING! DO NOT exceed the wattage capacity of the generator.
4.3.1 Start the engine and ensure the green output indicator light illuminates (fig.2).
4.3.2 Connect the equipment to the generator AC outlet (fig.2).
4.3.3 The output indicator light will remain on during normal operation. If the generator overloads, or there is a short in the connected
appliance, the red overload indicator light will illuminate (fig.2) and current to the connected appliance will be cut off.
4.3.4 If the red overload indicator light illuminates, stop the engine at once and investigate the source of the overloading.
Note: When an electric motor is started, both the overload indicator light and the output indicator light may come ON
simultaneously. If the overload indicator extinguishes after approximately four seconds, then this is normal.
4.4
DC APPLICATIONS - CHARGING A VEHICLE BATTERY
WARNING! DO NOT exceed the wattage capacity of the generator.
Note: The DC socket can be used whilst the AC power is in use. If using both simultaneously, DO NOT exceed the total power for
both AC and DC. The DC circuit has an overload protector that may trip in certain circumstances. If this happens, wait for a
minute and then push in the protector reset button (fig.2) to resume operation.
Note: In DC operation, turn the economy control switch to the OFF "0" position.
4.4.1 Connect the supplied charging cables to the DC outlet of the generator and then to the battery terminals ensuring that the correct
polarity is observed.
Note: When charging a battery installed in a vehicle, disconnect the vehicle battery earthing cable. Reconnect the earthing cable
after charging has been completed. Care should be taken when charging batteries, always refer to the battery manufacturer's
guidelines.
4.4.2 Start the generator's engine to charge battery. When charged sufficiently, stop generator and disconnect all cables.
4.5
SHUT DOWN PROCEDURE
4.5.1 Switch off the connected equipment and disconnect from the outlet.
4.5.2 Turn the engine switch to the OFF "0" position.
4.5.3 Turn the fuel tap to the 'OFF' position.
4.5.4 Close the fuel cap vent.
fig.3
© Jack Sealey Limited
fig.4
fig.5
Original Language Version
G1000E.V4 Issue:2(SP)-19/08/13