Conversion from one type of gas
to another, should only be under-
taken by an approved and registered
gas installer in strict accordance with
current local and national safety and
building regulations.
Disconnect the hob from the electri-
city supply and turn off the gas sup-
ply.
Jet table
The jet markings refer to a ¹/₁₀₀ mm
bore diameter.
Gas type
Main jet
Natural gas H
2x 1.04/0.72
Liquid gas
2x 0.66/0.46
Changing the jets
Disconnect the hob from the electri-
city supply and turn off the gas sup-
ply.
When converting to another type of
gas, both the main and small jets
need to be changed.
Converting to another gas type
Changing the main jets
Small jet
0.88/0.42
0.52/0.23
Remove the burner caps and
Using an M7 socket spanner, un-
Fit the correct jets securely (see jet
Secure the jets against inadvertent
burner head .
screw the main jets .
table).
loosening with sealing wax.
59