Download Print this page

Sealey SA51 Instructions page 3

Air needle scaler

Advertisement

5. MAINTENANCE
WARNING! Disconnect needle scaler from air supply before changing accessories, servicing
or performing maintenance. Replace or repair damaged parts. Use genuine parts only.
Unauthorised parts may be dangerous and will invalidate the warranty.
Note: Numbers in brackets refer to item numbers in the parts diagram.
5.1.
To replace the needles (16), unscrew the needle tube (19) from the barrel sleeve (12).
Replace the appropriate needles. Use only genuine Sealey needles. Screw the needle tube
(19) onto the barrel sleeve (12) and tighten.
5.2.
Lubricate the needle scaler daily with a few drops of Sealey air tool oil dripped into the air
inlet.
5.3.
Clean the needle scaler after use.
5.4.
Loss of power or erratic action may be due to the following:
a) Excessive drain on the air line. Moisture or restriction in the air pipe. Incorrect size or type
of hose connectors. To remedy check the air supply and follow instructions in chapter 3.
b) Grit or gum deposits in the needle scaler may also reduce performance. Flush the
needle scaler out with gum solvent oil or an equal mixture of SAE No 10 oil and paraffin.
Allow to dry before use.
5.5.
For a full service contact your local Sealey service agent.
5.6.
When not in use, disconnect from air supply, clean needle scaler and store in a safe, dry,
childproof location.
This tool may cause Hand Arm Vibration Syndrome if its use is not managed adequately.
This tool is subject to the vibration testing section of the Machinery Directive 2006/42/EC.
This tool is to be operated in accordance with these instructions.
This tool has been tested in accordance with: EN ISO 28927-2:2009 & BS EN ISO 15744:2008.
Declaration and verification of Vibration Emission figures are in accordance with EN 12096:1997
Measured vibration emission value (a):
Uncertainty value(k):
Please note that the application of the tool to a sole specialist task may produce a different average vibration emission.
We recommend that a specific evaluation of the vibration emission is conducted prior to commencing with a specialist task.
A health and safety assessment by the user (or employer) will need to be carried out to determine the suitable duration of use for
each tool.
NB: Stated Vibration Emission values are type-test values and are intended to be typical.
Whilst in use, the actual value will vary considerably from and depend on many factors.
Such factors include; the operator, the task and the inserted tool or consumable.
NB: ensure that the length of leader hoses is sufficient to allow unrestricted use, as this also helps to reduce vibration.
The state of maintenance of the tool itself is also an important factor, a poorly maintained tool will also increase the risk of
Hand Arm Vibration Syndrome.
Health surveillance.
We recommend a programme of health surveillance to detect early symptoms of vibration injury so that management procedures
can be modified accordingly.
Personal protective equipment.
We are not aware of any personal protective equipment (PPE) that provides protection against vibration injury that may result from
the uncontrolled use of this tool. We recommend a sufficient supply of clothing (including gloves) to enable the operator to remain
warm and dry and maintain good blood circulation in fingers etc. Please note that the most effective protection is prevention, please
refer to the Correct Use and Maintenance section in these instructions. Guidance relating to the management of hand arm vibration
can be found on the HSC website www.hse.gov.uk - Hand-Arm Vibration at Work.
NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
IMPORTANT: No liability is accepted for incorrect use of this product.
WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.
INFORMATION: For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.
© Jack Sealey Limited
WARNING! – Risk of Hand Arm Vibration Injury.
8.56 m/s²
1.34 m/s²
Environmental Protection.
Recycle unwanted materials instead of disposing of them as waste.
All tools, accessories and packaging should be sorted, taken to a recycle
centre and disposed of in a manner which is compatible with the environment.
Sole UK Distributor, Sealey Group,
Kempson Way, Suffolk Business Park,
Bury St. Edmunds, Suffolk,
IP32 7AR
Original Language Version
www.sealey.co.uk
01284 757500
W e b
01284 703534
sales@sealey.co.uk
email
SA51 Issue: 5(SP) - 20/09/13