Technical Data; Front Panel; Technical Data Of The Total Device - Bosch Rexroth IndraControl VPP 21.1 Series Project Planning Manual

The operator terminals vpp 21 are pc-based machine operator terminals
Table of Contents

Advertisement

VPP 21.1
4

Technical Data

4.1

Front Panel

4.2

Technical Data of the Total Device

DOK-SUPPL*-VPP*21.1***-PR02-EN-P
VPP 21.1 BQ
Display
Operation
Interface
Front panel IP 64 according to DIN 40 050, IEC 529
Degree of
protection
Fig. 4-1:
Technical data of the front panel
Degree of protection
Weight
Nominal input voltage
Input voltage range
Noise and surge immunity
24 volts power supply unit:
Maximum power consumption
Input current
Output voltages
+ 5 V
+ 12 V
Max. output power
Efficiency
Fig. 4-2:
Technical data of the total device
1
The power supply unit requires a maximum of 48 W (24 V, 2 A) from
the 24 VDC supply.
Additionally, a maximum of 24 W (24 V, 2 x 0,5 A) required for the two
24 V outputs are also taken from the 24 VDC supply.
14" TFT, 1024 * 768 pixels
Keys
Bosch Rexroth Design
IP 40 (for closed doors)
11.00 kg (key device VPP21.1 BQ)
9.15 kg
(touch device VPP21.1 BP)
24 VDC
24 VDC +20%, -15%
Umax = 35 V (for t < 100 ms)
1
48 W
2.0 A for nominal voltage 24 V
Current (max.)
6 A
0.7 A
38.4 W
0,8
4-1
Technical Data
VPP 21.1 BP
Touch
1
Tolerance
(incl. residual ripple)
+/- 5 %
+/- 5 %