Download Print this page

Specification; Operation; Control Functions - Sealey GI2300 Instructions For Use Manual

Inverter generator 2300/3500w 230v 4-stroke engine

Advertisement

2. introDuction
Heavy-duty frame provides full protection and incorporates carry handles for portability. inverter generator suitable for running sensitive
electrical equipment. Produces a clean AC current to match the load. Long running time of up to 8 hours on a full tank of fuel. Fitted with two
230V 13 Amp sockets. Increased fuel efficiency compared to standard generators. Features oil warning light, overload indicator and sight
glass to monitor fuel level.

3. specification

model no ................................Gi2300.........................Gi3500
motor Power ........................... 2.3KW...........................3.5KW
motor type ................4-Stroke Petrol..............4-Stroke Petrol
output ............................. 230V-50Hz....................230V-50Hz
current rating ...........................8.3A.............................15.2A
continuous Power rating......2000W...........................3200W
max. Power rating ................2300W...........................3500W
fuel tank capacity ................... 13ltr................................13ltr
max. running time ................. 13Hr..................................8hr
noise rating ...................... 95dB(A)..........................95dB(A)
noise pressure level ............... 74db................................74db
dry Weight .......................... 35.1Kg............................35.5Kg
dimension (WxdxH) ...440x520x470mm......440x520x470mm
fuel ....................... unleaded Petrol..............unleaded Petrol

4. operation

4.1.
Description fig.1.
1. control panel
2. choke Knob
3.inverter cover
4. Fuel cock knob
5. recoil starter
6. Muffler
7. Muffler cover
8. Fuel tank
9. Fuel tank cap
10. fuel gauge
11. Air filter
4.2.
Control Panel fig.2.
1. oil warning light
2. Ac pilot light
3. overload indicator light
4. Economy control switch
5. engine switch
6. dc socket
7. earth terminal
8. DC protector
9. AC socket
4.3.

control functions

4.3.1.
engine switch
ignition circuit is switched off
ignition circuit is switched on
4.3.2.
oil warning light (yellow)
When the oil level falls below the lower level , the oil warning light fig.3.1. comes on
the engine then stops automatically. Until the oil is refilled the engine will not start.
if the engine stalls or does not start, turn the engine switch to "on" and then pull
recoil starter cord. If the oil warning light flickers for a few seconds, there is
insufficient oil. top up oil and restart.
4.3.3.
overload indicator light (red)
the overload indicator light (3) comes on when an overload is detected, the inverter control unit overheats, or the Ac output
voltages rise. the Ac protector will trip and stop power generation in order to protect the generator. the Ac pilot light (Green) will
go off and the overload indicator light (red) will stay on, the power generation will stop. When this happens proceed as follows.
turn off any connected electric devices and stop the engine.
reduce the total wattage of connected appliance into the rated output.
check for blockages in the cooling air inlet and around the control unit. if any blockages are found, remove.
After checking , restart the engine. Note: The overload indicator light may come on for a few seconds at first when using electrical
© Jack sealey limited
fig.1
Original Language Version
fig.2
fig.3
GI2300,GI3500 Issue 2 (fig1) 19/04/18

Advertisement

loading

This manual is also suitable for:

Gi3500