Test Mode - Pioneer AVIC-505 Service Manual

Mobile navigation system
Hide thumbs Also See for AVIC-505:
Table of Contents

Advertisement

AVIC-505

7.2.2 TEST MODE

- Error Number Indication
If the CD should fail to operate or if an error has taken place during operation the player will enter into the error
mode, and the cause of the error will be numerically indicated.
This is aimed at assisting in analysis or repair.
(1) Basic Means of Display
· With ERROR indicated in "MODE" on IP-BUS Display data, an error code is transmitted by the use of MIN and SEC.
The MIN and SEC data will be identical.
· Examples of Display
(2) Error Codes
Error
Classification
Code
10
ELECTRIC
11
ELECTRIC
12
ELECTRIC
14
ELECTRIC
17
ELECTRIC
19
ELECTRIC
30
ELECTRIC
A0
SYSTEM
"defects" means scratches, dirt etc an the surface of the disc.
- New Test Mode(aging operation and setup analysis)
The single CD player plays in normal mode. After being set up, it will display FOK (focus), LOCK (spindle), subcode,
sound skip, protection against a mechanical error or the like, occurrence of an error, cause and time of an expiry, if
any, (and disc number).
During the setup, the CD software operation status (internal RAM and C-point)is displayed.
(1) How to enter NEW TEST Mode
See the test mode flow chart Page 63.
88
ERROR-XX
Description
Carriage home failure
Focus failure
SETUP failure
Subcode failure
Mirror failure
Set up failure
Set up failure
Search time out
Power failure
Cause/Detail
Carriage doesn't move to or from the innermost position
→Home switch failed and/or carriage immobile
Focus failed
→Defects, disc upside-down, severe vibration
Spindle failed to lock or subcode unreadable
→Spindle defective, defect, severe vibration
Unrecorded CD-R
The disc is upside-down, defects, vibration
AGC protect failed
→Defects, disc upside-down, severe vibration
Tracking error waveform is too unbalanced (>50%) or
level is too small
→The P.U.unit or tracking error circuitry is N.G.
Failed to reach target address
→Carriage/tracking defective and/or defects
Power overvoltage or short circuit detected
→Switching transistor defective and/or power abnormal