Fujitsu PRIMERGY Econel 200 S2 Service Supplement Manual
Fujitsu PRIMERGY Econel 200 S2 Service Supplement Manual

Fujitsu PRIMERGY Econel 200 S2 Service Supplement Manual

Hide thumbs Also See for PRIMERGY Econel 200 S2:

Advertisement

Quick Links

PRIMERGY Econel 200 S2
Server
Service Supplement
Edition February 2007

Advertisement

Table of Contents
loading

Summary of Contents for Fujitsu PRIMERGY Econel 200 S2

  • Page 1 PRIMERGY Econel 200 S2 Server Service Supplement Edition February 2007...
  • Page 2: Copyright And Trademarks

    Gesellschaft für Technik-Dokumentation mbH www.cognitas.de Copyright and Trademarks Copyright © 2007 Fujitsu Siemens Computers GmbH. All rights reserved. Delivery subject to availability; right of technical modifications reserved. All hardware and software names used are trademarks of their respective manufacturers.
  • Page 3: Table Of Contents

    Contents Introduction ......5 Overview of the documentation ....5 Notational conventions .
  • Page 4 Contents Appendix ......35 Board layout ......35 5.1.1 Chassis ID board .
  • Page 5: Introduction

    Introduction The PRIMERGY Econel 200 S2 server is an Intel-based server for workgroups and small networks. The server is suitable for use as a file server and also as an application, information or Internet server. Overview of the documentation Concept and target group of this manual This Service Supplement completes the information given in the Operating Manual, the Options Guide and the Technical Manual of the system board.
  • Page 6 Overview of the documentation Introduction Information/procedure Manual Detailed safety notes Safety notes and other important information Features and technical data of the server Operating Manual Installation and operation, among other things: – External ports on the server – Operation – Configuration of the server Troubleshooting Information about the system board: Technical Manual...
  • Page 7: Notational Conventions

    Introduction Notational conventions Information/procedure Manual Replacement routines: Service Supplement – Replacing the operating panel cable – Replacing the USB cable (front side) – Replacing the temperature sensor – Replacing the power supply unit – Replacing the intrusion switch – Replacing the Chassis ID board –...
  • Page 9: Procedure

    Procedure CAUTION! The actions described in this manual should only be performed by service personnel. Ê Before doing anything else, please take notice of chapter “Safety notes” on page 11 et seq. . Ê Make sure all necessary manuals (see service DVD) are available; possibly print of the PDF files.
  • Page 11: Safety Notes

    Safety notes The following safety notes are also provided in the “Safety notes and other important information. This device complies with the relevant safety regulations for information technology. CAUTION! The actions described in this manual should only be performed by service personnel.
  • Page 12 Safety CAUTION! ● The ON/OFF button does not disconnect the device from the mains voltage. To disconnect the line voltage completely, remove the power plug from the grounded insulated socket. ● Always connect the device and the attached peripherals to the same power circuit.
  • Page 13 Safety CAUTION! ● Only install system expansions that satisfy the requirements and rules governing safety and electromagnetic compatibility and relating to telecommunications terminal equipment. If you install other expan- sions, you may damage the system or violate the safety regulations and regulations governing RFI suppression.
  • Page 14 Safety Batteries CAUTION! ● Incorrect replacement of batteries may lead to a risk of explosion. The batteries may only be replaced with identical batteries or with a type recommended by the manufacturer (see the technical manual for the system board). Do not throw batteries into the trash can.
  • Page 15 Safety Notes on handling CDs/DVDs and CD/DVD drives CAUTION! ● Use only CDs/DVDs in proper condition in the CD/DVD drive of your server to prevent data loss, damage to the device and injuries. Therefore, check each CD/DVD for damage, cracks, breakage etc. ●...
  • Page 16 Safety Modules with electrostatic-sensitive components: Systems and components that might be damaged by electrostatic discharge (ESD) are marked with the following label: Figure 1: ESD label When you handle components fitted with ESDs, you must observe the following points under all circumstances: Remove the power plug from the power socket before inserting or removing ●...
  • Page 17: Replacement Routines

    Replacement routines CAUTION! Refer to the safety notes in chapter “Safety notes” on page 11 et seq. . Preparation You will find a detailed description with photos in the Econel 200 S2 Options Guide. 4.1.1 Opening the server Ê Terminate all applications and shut down the server correctly. Ê...
  • Page 18: Removing The System Fan

    Preparation Replacement routines 4.1.3 Removing the system fan Ê Remove the side cover as described in section “Opening the server” on page 17. Ê Remove the processor fan 2 as described in section “Removing the processor fan 2” on page 17. Ê...
  • Page 19: Removing The Front Cover

    Replacement routines Preparation Ê Disconnect the plug of the processor fan cable from the system board (connector Fan1 CPU, see system board foil D2530). Ê Pull the lock bar in direction of the front side. Ê Pull the system fan a little forward to disengage its hooks at the rear side of the server and take out the processor fan 1.
  • Page 20 Preparation Replacement routines Figure 3: Removing the front cover Ê Unhook the front cover carefully and remove it. Service Supplement Econel 200 S2...
  • Page 21: Replacing The Operating Panel Cable

    Replacement routines Replacing the operating panel cable Replacing the operating panel cable Part number: A3C40060863 Ê Remove the side cover as described in section “Opening the server” on page 17. Ê Remove the front cover as described in section “Removing the front cover” on page 19.
  • Page 22 Replacing the operating panel cable Replacement routines Figure 5: Removing the LEDs Ê Extract the holder of the LED at the inside of the chassis and push the LED out of the holder from the front side. Remove the second LED in the same way.
  • Page 23: Replacing The Usb Cable (Front Side)

    Replacement routines Replacing the USB cable (front side) Replacing the USB cable (front side) Part number: A3C40082391 Ê Remove the side cover as described in section “Opening the server” on page 17. Ê Remove the front cover as described in section “Removing the front cover” on page 19.
  • Page 24 Replacing the USB cable (front side) Replacement routines Figure 7: Unhooking the holder Ê Unhook the holder on the top side (see arrow) and pull out the USB cable frontward. Ê Thread the new USB cable through the recess, hook the holder on the top side and fasten the holder with one screw.
  • Page 25: Replacing The Temperature Sensor

    Replacement routines Replacing the temperature sensor Replacing the temperature sensor Part number: T26139-Y3850-V229 Ê Remove the side cover as described in section “Preparation” on page 17. Figure 8: Removing the temperature sensor Ê Release the temperature sensor from the cable clamp and remove the connector from the operating panel cable (see circle).
  • Page 26: Replacing The Power Supply Unit

    Replacing the power supply unit Replacement routines Replacing the power supply unit Ê Remove the side cover as described in section “Preparation” on page 17. Ê Remove the processor fan 2 as described in section “Removing the processor fan 2” on page 17. Ê...
  • Page 27 Replacement routines Replacing the power supply unit Figure 10: Disengaging the power supply unit Ê Push the power supply unit toward the front of the server until the mounting bracket (see arrow) disengages from the chassis. Ê Take out the power supply unit sideward. Figure 11: Mounting the bracket onto the new power supply unit Ê...
  • Page 28 Replacing the power supply unit Replacement routines Figure 12: Inserting the power supply unit Ê Push the power supply unit in direction of the server’s rear side until it engages in the chassis. Ê Fasten the power supply unit with four screws on the server’s rear side (see figure 9 on page 26).
  • Page 29: Replacing The Intrusion Switch

    Replacement routines Replacing the intrusion switch Replacing the intrusion switch Part number: A3C40082393 The intrusion switch monitors the removing of the side cover of the housing. Ê Remove the side cover as described in section “Preparation” on page 17. Ê Remove the processor fan 2 as described in section “Removing the processor fan 2”...
  • Page 30: Replacing The Chassis Id Board

    Replacing the Chassis ID board Replacement routines Ê Press sideward on the hooks of the new intrusion switch holder and press the holder into the chassis. Ê Install the processor fan 2 (for a detailed description see the Options Guide). Ê...
  • Page 31: Replacing The System Board

    The ID PROM on the new Chassis ID board must be programmed with the help of the „ChassisIDProm Tool“. You will find the tool on the ServerSupport CD and/or it can be downloaded from the Fujitsu Siemens Computers Service and Support Internet page (FSC Web-Server/URL: http://www.fsc-pc.de). Replacing the system board Ê...
  • Page 32 Replacing the system board Replacement routines Figure 15: Removing the screws Ê Remove the 6 screws from the system board. Ê Lift the system board slightly using the marked socket of PCI slot 6 (see arrow). In this way you lift the system board out of the centering ring of the spacer bolt.
  • Page 33 Replacement routines Replacing the system board Ê Unpack the new system board, place it on an antistatic surface and check the settings (for description see the Technical Manual for the system board). Ê Insert the system board into the housing by holding it at a slight angle and sliding the connectors into the connector panel.
  • Page 35: Appendix

    Appendix Board layout The board layout of the system board is described in the Technical Manual of the system board D2530. 5.1.1 Chassis ID board Part number: A3C40070714 Connector I C cable (Y3718-V701/A3C40060864) Service Supplement Econel 200 S2...
  • Page 37: Index

    Index traverse Chassis ID board 30, USB cable (front side) ESD (devices sensitive to electrostatic discharge) ESD-sensitive devices front cover intrusion switch light-emitting diode (LED) lithium battery meaning of the symbols memory air duct notational conventions note about the laser operating panel cable power supply unit processor fan 1...
  • Page 39 Information on this document On April 1, 2009, Fujitsu became the sole owner of Fujitsu Siemens Compu- ters. This new subsidiary of Fujitsu has been renamed Fujitsu Technology So- lutions. This document from the document archive refers to a product version which was released a considerable time ago or which is no longer marketed.

Table of Contents