Download Print this page

Specifications - GE Lumination BL44 Series Installation Manual

Advertisement

m
2 0 c
1 5 -
3
Mount fixture into grid system. The brackets should be
15–20cm (6–8 in.) from the ends.
5
For added safety, use additional screw to permanently fix
bracket to grid. Optionally, mounting brackets can be fixed
directly to the roof with appropriate mounting wire and
hardware (not included).

Specifications

Input Voltage
Input Power/foot (complete system)
Input Frequency
Power Factor
CCT
Color Consistency
CRI
THD
Control
Warranty
Mounting
Environmental Operating Temperature Range
Environmental Humidity (non-condensing)
Environmental Storage Temperature Range
Weight
IP Rating
GE Lighting Solutions • 1-888-MY-GE-LED • www.gelightingsolutions.com
GE Lighting Solutions, LLC is a subsidiary of the General Electric Company. Lumination is a trademark of GE Lighting Solutions, LLC. The GE brand and logo are trademarks of the General Electric Company.
© 2012 GE Lighting Solutions, LLC. Information provided is subject to change without notice. All values are design or typical values when measured under laboratory conditions.
Screw for safety
High Lumen Output Series
120 – 277V
9W
50/60Hz
>0.9
3000K, 3500K, 4000K
4-step
83
<20%
0-10V/DALI
5 years
Recessed system - A type grids
-10°C to +40°C
20 to 80% Non-condensing, dry location rated
-40°C to +60°C
<7 kg
IP30
Conforms to the following standards:
1 - 8 8 8 - 6 9 - 4 3 - 5 3 3
4
Using a 5.5mm socket wrench, gently tighten nuts on
mounting brackets, being careful not to strip the threads.
Ceiling
6
After installation, remove green protective film from the
diffuser if applicable.
Medium Lumen Output Series
Recessed system - A type grids
20 to 80% Non-condensing, dry location rated
Remove green
protective film
120 – 277V
6W
50/60Hz
>0.9
3000K, 3500K, 4000K
4-step
83
<20%
0-10V/DALI
5 years
-10°C to +40°C
-40°C to +60°C
<8 kg
IP30
IND035-100412