Electrical Data; Power Section - Mains Supply - Bosch Rexroth IndraDrive C HCS03.1 Planning Manual

Drive controllers
Table of Contents

Advertisement

Rexroth IndraDrive C HCS03.1
6

Electrical Data

6.1

Power Section - Mains Supply

Designation
three-phase mains
connection
single-phase mains
connection
rotary field
total power factor TPF at
P
with / without mains
DC
choke
power factor of
fundamental component
DPF P
with / without
DC
mains choke
assigned mains choke
HNL01.1E-
mains input voltage range
mains frequency
mains input continuous
current at P
DC cont
maximum inrush current
(at max. input voltage)
mains connection power
at P
;
DC_cont
U
=AC400V; with
LN
HNL01.1E
mains connection power
at P
;
DC_cont
U
=AC400V; without
LN
HNL01.1E
DOK-INDRV*-HCS03.1****-PR02-EN-P
Note:
The current and power data below apply when the allowed
motor cable length is complied with (see data in section "X5,
Motor Connection"). They refer to 3AC400 V.
Symbol
Unit
HCS03.1E-
W0070
cosφ=1/λ
0,85/0,57
L
h1
0,95/0,64
cosφ
0571-N0050-A-
500-NNNN
U
V
LN
f
Hz
LN
I
A
50
L,cont
I
A
2,8
L, trans max
(on)
S
kVA
35
LN
S
kVA
22,6
LN
Fig. 6-1:
Electrical data: power section - mains supply
HCS03.1E-
HCS03.1E-
W0100
W0150
allowed
not allowed
no rotary field condition
0,83/0,59
0,81/0,61
0,95/0,67
0,94/0,70
0362-N0080-A-
0240-N0106-A-
500-NNNN
500-NNNN
3AC400 ... 500 +10% -15%
50 ... 60 ± 2 Hz
80
106
5,7
5,7
55,2
72,9
40,3
54
6-1
Electrical Data
HCS03.1E-
W0210
0,78/0,62
0,93/0,73
0170-N0146-A-
500-NNNN
146
17
99,3
76