Download Print this page

Sealey SAC41 Instructions Manual page 4

Air cooler, heater purifier & humidifier

Advertisement

4.3
Preparing the unit for cooling.
The unit produces a cooling effect by
evaporating water which is in a tank in
the base of the unit. Before use the
water tank must be filled up.
Ensure that the unit is unplugged from
the mains supply before topping up with
water.
Open the top cover of the unit and pour
water into the small compartment as
shown on the right. Do not pour water
into the larger ice compartment. The
water is transferred to the lower tank by
a tube. Check the level of water in the
tank by looking at the water level
indicator at the bottom, front, right of the
unit. The level should be between 'max'
and 'low'.
4.3.1 For an additional cooling effect place the
ice packs supplied into the draw in the
side of the unit (see right) and close the
draw. The ice packs should be previously
prepared by filling with water and freezing
overnight.
4.3.2 Additionally, or as an alternative, the
cooling effect can be enhanced by adding
ice to the larger compartment under the
top cover (see right). Do not pour water
into the ice compartment.
4.4
USING THE UNIT TO COOL A ROOM.
4.4.1 Plug the unit into the mains supply.
4.4.2 Switch the unit on by pressing the
ON/OFF button.
4.4.3 Make sure that the air flow control lever
is moved downwards to the 'COOL'
position.
4.4.4 Press the 'COOL' button once to
activate the cooling function.
The 'Icy Breeze' indicator lamp above the button
will illuminate. The fan will start to run at the speed
last set.
4.4.5 Adjust the speed of the fan if required using the
'SPEED' button.
4.4.6 Activate the louvre oscillation from side to side if
required using the 'WIND' button. Adjust the air
flow up or down manually.
4.4.7 Set the timer if required using the 'TIMER' button.
4.4.8 To stop the cooling function press the 'COOL'
button again and the indicator light will go out.
4.5
USING THE UNIT TO HEAT A ROOM.
4.5.1 Plug the unit into the mains supply.
4.5.2 Switch the unit on by pressing the ON/OFF button.
4.5.3 Make sure that the air flow control lever is moved
upwards to the 'WARM' position.
4.5.4 Press the 'WARM' button once or twice to select
the heating level. The indicator lights above will
show the heating level selected. The fan will start
to run at the speed last set.
4.5.5 Adjust the speed of the fan if required using the
'SPEED' button.
4.5.6 Activate the louvre oscillation from side to side if
required using the 'WIND' button. Adjust the air
flow up or down manually.
4.5.7 Set the timer if required using the 'TIMER' button.
Fig.3
4.5.8 To stop the heating function press the 'WARM'
button until all the lights are out.
4.5.9 When the unit is switched OFF using the 'ON/OFF'
button the fan will continue to run for about 30secs.
During this time the power light will flash until the
unit shuts down.
4.6
USING THE UNIT TO HUMIDIFY.
4.6.1 In a dry and warm atmosphere the cooling action
of the unit naturally adds humidity to the air due to
the fact that the cooling action is provided by the
evaporation of water.
4.7
USING THE UNIT TO FILTER AND PURIFY.
4.7.1 The air for both heating and cooling is drawn into
the unit through an activated carbon filter and thus
cleans the air of dust and other particles.
4.7.2 The unit also contains a negative ion generator
known to produce cleaner fresher air and reduce
airborne odours. The ion generator starts to work
as soon as the unit is switched on and works in
both heating and cooling modes.
4.8
USING THE UNIT AS A FAN ONLY.
4.8.1 If neither heating or cooling is selected on the
control panel the unit will act as a 3 speed fan.
In this mode both the 'TIMER' and 'WIND' functions
can be used.
SAC41 - 1 - 05/12/06

Advertisement

loading