7
Installation information for cylinder without
solar coil
Double-shelled hot water heater, copper (C).
Fig. 77 360 C
Fig. 78 360 C
[1]
Flow line from heat pump
[2]
Sensor pocket/thermometer connection
[3]
Return to heat pump
200-300 R/C, 200-300 R, 360 C – 6 720 801 192 (2017/07)
6720646738-10.1I
1
2
2
3
6720646738-11.1I
Installation information for cylinder without solar coil
3
2
1
Fig. 79 Ceiling connections
[1]
Venting
[2]
Hot water
[3]
Cold water
Fig. 80 Ceiling connection dimensions 360
Filling the water heater
WARNING: The water heater can crack if filling is
performed in the wrong order.
▶ Fill and pressurise the water heater before filling the
heating system.
Do not forget to vent after filling the outer shell and
commissioning the system.
695
100
125 125
6720646738-13.1I
35