5.4 The TD Function List
5.4.1 Motor FLA, Service Factor and Overload Protection Functions
Fn
Group
Motor Nameplate FLA
F001
Motor FLA must be programmed
for proper unit operation.
F002
Motor Nameplate Service Factor
F003
Overload Class During Start
F004
Overload Class During Run
F005
Overload Reset
F006-
Reserved
F009
5.4.2 Starting Mode Functions
Fn
Group
Ramp Select
F010
VR = Voltage Ramp,
CR = Current Ramp
F011
Initial Voltage of Ramp 1
F012
Initial Current of Ramp 1
F013
Accel Ramp Time of Ramp 1
F014
Max Current Limit of Ramp 1
F015
Initial Voltage of Ramp 2
F016
Initial Current of Ramp 2
F017
Accel Ramp Time of Ramp 2
F018
Max Current Limit of Ramp 2
5.4.3 Jog Mode Functions
Fn
Group
F019
Voltage Jog
F020
Time of Voltage Jog
F021
Current Jog
Note 1: Current percentages are based on Motor Full Load Amps (FLA) as entered in F001.
Digital Solid State Soft Starter 48 - 1250A
Function
50-100% of starter Max. Amp rating
Upper limit of range automatically
adjusts downward as Service
Factor is increased
1.00 - 1.30
5 - 30 NEMA / UL Class
Overload Time / Trip Curve
5 - 30 NEMA / UL Class
Overload Time / Trip Curve
0=Manual
1=Auto
2=Disabled Overload
Reserved
Function
Range is 1 - 4
Setting to #1: Ramp 1 = VR, Ramp 2 = VR
Setting to #2: Ramp 1 = CR, Ramp 2 = CR
Setting to #3: Ramp 1 = VR, Ramp 2 = CR
Setting to #4: Ramp 1 = CR, Ramp 2 = VR
0-100%
0-600% (note1)
1-120 seconds
200 - 600% (note1)
0-100%
0-600% (note1)
1-120 seconds
200 - 600% (note1)
Function
5 - 100%
1 - 20 Seconds
100 - 500%
Adjustment
Range
Adjustment
Range
Adjustment
Range
TD - Series
- 17 -
Setting
Factory
Increments
Setting
0
1 amp
(Starter disabled
until set to FLA)
0.05
1.0 SF
5
Class 10
5
Class 10
1
0 (Manual)
Reserved
Reserved
Setting
Factory
Increments
Setting
1
1 (VR1-VR2)
1%
60%
1%
200%
1 second
10 seconds
1%
350%
1%
60%
1%
200%
1 second
10 seconds
1%
350%
Setting
Factory
Increments
Setting
1%
50%
1 second
10 seconds
1%
150%
Section
5.5.1
5.5.1
5.5.1
5.5.1
5.5.1
5.5.1
Section
5.5.2
5.5.2
5.5.2
5.5.2
5.5.2
5.5.2
5.5.2
5.5.2
5.5.2
Section
5.5.3
5.5.3
5.5.3

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Td series

Table of Contents