BLOWER AND FAN SERVICE

The air conditioner will have to be removed from the window to service the indoor blower/motor and the
outdoor fan/motor.
To Service Blower Fan:
In order to access the fan and motor, you must
diasassemble the spacer plastic fan housing.
1. With front grille removed, cut foam gasket
on both sides of louver assembly. Remove
two screws and lift out assembly.
2. Remove two screws and two ground
wires. Lift out metal blower fan housing.
3. Remove spacer bracket to remove plastic
housing for motor access.
LOUVER ASSEMBLY
BLOWER FAN
5/16" NUT
REMOVE LOUVER ASSEMBLY
REMOVE HOUSING SIDE
LIFT OUT METAL BLOWER HOUSING
REMOVE SPACER BRACKET